Removal Procedure
- Remove the left closeout insulator Panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel, Gages, and Console.
- Remove the left knee bolster bracket. Refer to
Driver Knee Bolster Bracket Replacement
in Instrument Panel, Gages, and Console.
- Disconnect the inside air temperature sensor
assembly (1) electrical connector.
- Remove the screws (2) from the inside air temperature sensor assembly
.
- Remove the inside air temperature sensor (1)
from the instrument panel.
Installation Procedure
- Install the inside air temperature sensor (1)
to the instrument panel.
- Install the inside air temperature sensor assembly (1)
screw (2).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Tighten the screw (2).
Tighten
Tighten the screw to 1.4 N·m (12 lb in).
- Connect the inside air temperature sensor assembly (1) electrical
connector.
- Install the left knee bolster bracket. Refer to
Driver Knee Bolster Bracket Replacement
in Instrument Panel, Gages, and Console.
- Install the left closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel, Gages, and Console.