Table 1: Climate Control Panel (CCP) Scan Tool Data List
Table 2: Heating and Air Conditioning Scan Tool Data List
Table 3: Instrument Panel Cluster Scan Tool Data List
Table 4: PCM Scan Tool Data List

Use the Scan Tool Data Display Values and Definitions Information in order to assist in diagnosing the Instrument Panel Integration Module (IPM) problems. Compare the vehicles actual scan tool data with the typical data display value table information. Use the data information in order to aid in understanding the nature of the problem when the vehicle does not match with the typical data display values.

The scan tool data values were taken from a known good vehicle under the following conditions:

    • The ignition switch is in the ON position.
    • The engine is running at idle.
    • The vehicle is in PARK.
    • The doors are closed.
    • The windows are closed.
    • The A/C is ON.
    • The ambient air temperatures are at 22-27°C (70-80°F).

Climate Control Panel (CCP) Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F), dual zone OFF

A/C Off Switch

Inputs

On/Off

Off

Auto Switch

Inputs

On/Off

Off

Blower Speed Dec. Sw.

Inputs

On/Off

Off

Blower Speed Inc. Sw.

Inputs

On/Off

Off

Calibration ID

Module Information 1

4 digit numeric

9601

Defrost Switch

Inputs

On/Off

Off

De-Ice Switch

Inputs

On/Off

Off

Julian Date of Build

Module Information 2

3 digit numeric

varies

Last 4 Dig Product Ser. No.

Module Information 2

4 digit numeric

1506

Last 6 Digits Part No. 1-3

Module Information 1

3 digit numeric

235

Last 6 Digits Part No. 4-6

Module Information 1

3 digit numeric

806

Mode Override Dec. Sw.

Inputs

On/Off

Off

Mode Override Inc. Sw.

Inputs

On/Off

Off

Off Switch

Inputs

On/Off

Off

Passenger Cooler Sw.

Inputs

On/Off

Off

Passenger Warmer Sw.

Inputs

On/Off

Off

Passenger Zone Switch

Inputs

On/Off

Off

Rear Defog Switch

Inputs

On/Off

Off

Recirculate Switch

Inputs

On/Off

Off

Rom ID

Module Information 1

4 digit alphanumeric

9502

Year Module Built

Module Information 2

4 digit numeric

1999

Heating and Air Conditioning Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F), dual zone OFF

A/C Commanded

Inputs

Yes/No

Yes

A/C Defrost Solenoid

Outputs

On/Off

Off

A/C Possible

Inputs

Yes/No

Yes

Act. Dr. Mix Door Pos.

Data

Counts

varies

Act. Pass. Mix Door Pos.

Data

Counts

varies

Actual Air Mode

Inputs

Heater

Bi-Level A/C

A/C

Heater/Defrost

Defrost

varies

Air Down Solenoid

Outputs

On/Off

Off

AIR Up Solenoid

Outputs

On/Off

Off

Calibration ID

Module Information 1

4 digit numeric

6905

Com. Dr. Mix Door Pos.

Data

Counts

varies

Com. Pass. Mix Door Pos.

Data

Counts

varies

Commanded Blower

Data

Percentage

0-99%

Commanded Cooling Fan

Data

Off/Low/High

varies

Coolant Temperature

Data

°C/°F

varies

Driver Mix Number

Data

Counts

varies

Dual Zone Pot

Data

Counts

varies

Dual Zone Switch

Inputs

On/Off

Off

Engine Speed

Data

RPM

varies

Evaporator Inlet Temp.

Data

°C/°F

varies

Hi Refrig. Pressure Sw.

Inputs

Open/Closed

Closed

High Side Temperature

Data

°C/°F

varies

Ignition 0

Data

Volts

13.6 Volts

Ignition Counter

Data

0-50

varies

In Car Temperature

Data

°C/°F

varies

Julian Date of Build

Module Information 2

3 digit numeric

varies

Last 4 Dig Product Ser. No.

Module Information 2

4 digit numeric

1816

Last 6 Digits Part No. 1-3

Module Information 1

3 digit numeric

231

Last 6 Digits Part No. 4-6

Module Information 1

3 digit numeric

486

Low Refrig. Pressure Sw.

Inputs

Open/Closed

Closed

Outside Temperature

Data

°C/°F

varies

Park Brake Release

Outputs

On/Off

Off

Passenger Mix Number

Data

Counts

0-255 Counts

Program Number

Data

Counts

0-255 Counts

Raw Coolant Temperature

Open/Short Data

Counts

Open

Short

varies

Raw Evaporator Temp.

Open/Short Data

Counts

Open

Short

varies

Raw Highside Temperature

Open/Short Data

Counts

Open

Short

varies

Raw Inside Temperature

Open/Short Data

Counts

Open

Short

varies

Raw Outside Temperature

Open/Short Data

Counts

Open

Short

varies

Raw Solar Sensor

Open/Short Data

Counts

Open

Short

varies

Rear Blower

Data

Counts

0-124 Counts

Recirculation Solenoid

Outputs

On/Off

Off

Rom ID

Module Information 1

4 digit numeric

6111

Selected Air Mode

Inputs

Auto

Bi-Level

Econ-A/C-Off

Heater/Defrost

Man. A/C

Man. Defog

Man. Defrost

Man. Heat

Off

varies

Solar Sensor

Data

Counts

0-255 Counts

Vehicle Speed

Data

km/h

mph

0 km/h

0 mph

Year Module Built

Module Information 2

4 digit numeric

2001

Instrument Panel Cluster Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

Steering Wheel Controls

Data

Bottom Left Down

Bottom Left Up

Bottom Right Down

Bottom Right Up

Idle

Top Left Down

Top Left Up

Top Right Down

Top Right Up

varies

Steering Wheel Controls

Data

Counts

varies

PCM Scan Tool Data List

Scan Tool Parameter

Data List

Units Displayed

Typical Data Value

Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)

*A/C High Side Pressure Sensor (If Equipped)

Engine Data 2

Volts

0.00-5.00 Volts

A/C Relay Command

Engine Data 1

Engine Data 2

Engine Data 3

Misfire Data

On/Off

On

ECT

ALL

C/F

Varies