Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Do the backup lamps remain illuminated? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 |
Do the Backup Lamps remain illuminated? | Go to Step 4 | Go to Step 5 |
4 | Repair the short to voltage in the supply voltage circuit of the Backup Lamps. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 6 | -- |
5 | Replace the REVERSE relay. Refer to Relay Replacement in Wiring Systems. Did you complete the replacement? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |