Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Generator on-vehicle test which will test the generator independently from the vehicle wiring. | ||||
1 | Has the charging system check been performed? | -- | Go to Step 2 | Go to Charging System Check |
2 |
Does the green POWER lamp on the tester light? | -- | Go to Step 9 | Go to Step 3 |
3 |
Does the green POWER lamp on the tester light after the correct connections are verified? | -- | Go to Step 9 | Go to Step 4 |
4 | Connect a J 39200 DMM from the generator output terminal to the generator metal housing. Is the voltage above the specified value? | 12 V | Go to Step 18 | Go to Step 5 |
5 | Use a J 39200 DMM to measure the voltage from the battery positive (+) terminal to the battery negative (-) terminal. Is the voltage above the specified value? | 12 V | Go to Step 6 | Go to Step 8 |
6 |
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components. Is the circuit OK between the generator output terminal and the battery positive (+) terminal? | -- | Go to Step 7 | -- |
7 | Repair the poor connection or open circuit between the battery negative (-) terminal and the generator housing. Is the repair complete? | -- | Go to Step 2 | -- |
8 |
Is the battery OK? | -- | Go to Step 2 | -- |
9 |
Does the red DIAGNOSTIC lamp on the tester light? | -- | Go to Step 11 | Go to Step 10 |
10 | Perform the following test of the DIAGNOSTIC lamp of the J 41450-B :
Does the red DIAGNOSTIC lamp on the tester light when the jumper is connected? | -- | Go to Step 19 | Go to Step 18 |
11 |
Caution: Make sure that the load is completely turned off before connecting or disconnecting a carbon pile load tester to the battery. Otherwise, sparking could ignite battery gasses which are extremely flammable and may explode violently.
Does the red DIAGNOSTIC lamp on the J 41450-B light? | -- | Go to Step 19 | Go to Step 12 |
12 | Increase the engine speed to 2500 RPM. Does the red DIAGNOSTIC lamp on the J 41450-B light? | -- | Go to Step 19 | Go to Step 13 |
13 |
As the load is increased, is the generator capable of producing the amount of load test current specified in Generator Usage ? | -- | Go to Step 14 | Go to Step 19 |
14 | Maintain the engine speed at 2500 RPM and continue to operate the generator at the load test value. Is the red DIAGNOSTIC lamp on the J 41450-B lit? | -- | Go to Step 19 | Go to Step 15 |
15 |
Is the voltage above the specified value? | 0.5 V | Go to Step 22 | Go to Step 16 |
16 |
Is the voltage above the specified value? | 0.5 V | Go to Step 23 | Go to Step 17 |
17 |
Caution: Make sure that the load is completely turned off before connecting or disconnecting a carbon pile load tester to the battery. Otherwise, sparking could ignite battery gasses which are extremely flammable and may explode violently.
Does the vehicle have a wire in the L terminal cavity of the generator 4-way connector? | -- | System OK | Go to Step 24 |
18 | There is an internal problem in the J 41450-B . Replace the J 41450-B . Has the J 41450-B been replaced? | -- | Go to Step 2 | -- |
19 |
Important: Before generator repair or replacement, the L terminal circuit (if applicable) must be tested for resistance in order to avoid a repeat failure. Disconnect and examine the generator 4-way connector. Is there a wire in the L cavity of the generator connector? | -- | Go to Step 20 | Go to Step 24 |
20 |
Does the fuse blow? | -- | Go to Step 21 | Go to Step 25 |
21 | There is a short to B + voltage when the ignition switch is in the RUN position. The short may be a result of a miswired condition. The L terminal circuit must be a resistance circuit either through a charge indicator or the powertrain control module (PCM). If direct battery voltage is applied to the generator at the L terminal, the regulator will eventually be destroyed, causing a repeat failure. Repair the short to B + voltage in the L terminal circuit. Is the short circuit repaired? | -- | Go to Step 25 | -- |
22 |
Caution: Before servicing any electrical component, the ignition and start switch must be in the OFF or LOCK position and all electrical loads must be OFF, unless instructed otherwise in these procedures. If a tool or equipment could easily come in contact with a live exposed electrical terminal, also disconnect the negative battery cable. Failure to follow these precautions may cause personal injury and/or damage to the vehicle or its components. Is the repair complete? | -- | Go to Step 2 | -- |
23 |
Is the repair complete? | -- | Go to Step 2 | -- |
24 | The tester turns the generator on in a different way than the vehicle does, so an additional test is necessary. This Step is applicable only for vehicles that do not use an L terminal connection.
Is the resistance between the generator I/F and L terminals equal to or below the specified value? | 500 ohms | System OK | Go to Step 25 |
25 | Repair or replace the generator. Refer to Generator Replacement . Is the repair complete? | -- | Go to Step 2 | -- |