The torque converter clutch (TCC) solenoid valve is an electrical device that is used with the torque converter clutch pulse width modulation (TCC PWM) solenoid valve in order to control TCC apply and release. The TCC solenoid valve attaches to the transmission case assembly extending into the pump cover. The TCC solenoid valve receives ignition voltage through circuit 1020. The vehicle control module (VCM) controls the solenoid by providing the ground path on circuit 422. The VCM monitors the throttle position (TP) voltage, the vehicle speed, and other inputs in order to determine when to energize the TCC solenoid valve.
When the VCM detects a continuous open, short to ground, or short to power in the TCC solenoid valve circuit, then DTC P0740 sets. DTC P0740 is a type A DTC.
• | The system voltage is 10-19 volts. |
• | The engine speed is greater than 450 RPM for 5 seconds. |
• | The engine is not in fuel cutoff. |
DTC P0740 sets if one of the following conditions occurs for 5 seconds:
The VCM commands the solenoid ON and the voltage feedback remains high (B+).
The VCM commands the solenoid OFF and the voltage feedback remains low (0 volt).
• | The VCM illuminates the malfunction indicator lamp (MIL). |
• | The VCM inhibits TCC engagement. |
• | The VCM inhibits 4th gear if the transmission is in hot mode. |
• | The VCM freezes shift adapts from being updated. |
• | The VCM records the operating conditions when the Conditions for Setting the DTC are met. The VCM stores this information as Freeze Frame and Failure Records. |
• | The VCM stores DTC P0740 in VCM history. |
• | The VCM turns OFF the MIL during the third consecutive trip in which the diagnostic test runs and passes. |
• | A scan tool can clear the MIL/DTC. |
• | The VCM clears the DTC from VCM history if the vehicle completes 40 warm-up cycles without an emission-related diagnostic fault occurring. |
• | The VCM cancels the DTC default actions when the fault no longer exists and/or the ignition switch is OFF long enough in order to power down the VCM. |
• | Inspect the wiring at the VCM, the transmission connector and all other circuit connecting points for the following conditions: |
- | A backed out terminal |
- | A damaged terminal |
- | Reduced terminal tension |
- | A chafed wire |
- | A broken wire inside the insulation |
- | Moisture intrusion |
- | Corrosion |
• | When diagnosing for an intermittent short or open condition, massage the wiring harness while watching the test equipment for a change. |
• | With the TCC engaged, the TCC slip speed should be -20 to +50 RPM. |
The numbers below refer to the step numbers on the diagnostic table.
This step tests for voltage to the solenoid.
This step tests the ability of the VCM and wiring to control the ground circuit.
This step tests the resistance of the TCC solenoid valve and the automatic transmission (AT) wiring harness assembly.
Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Was the Powertrain On-Board Diagnostic (OBD) System Check performed? | -- | Go to Powertrain On Board Diagnostic (OBD) System Check in Engine Controls | |||||||||
2 |
Important: Before clearing the DTC, use the Scan Tool in order to record the Freeze Frame and Failure Records. Using the Clear Info function erases the Freeze Frame and Failure Records from the VCM. Are any of the following DTCs also set?
| -- | ||||||||||
3 | Inspect the TRANS fuse for an open. Refer to General Electrical Diagnosis in Wiring Systems. Is the fuse open? | -- | ||||||||||
Refer to Automatic Transmission Inline Harness Connector End View . Is the test lamp ON? | -- | |||||||||||
Refer to Automatic Transmission Inline Harness Connector End View . Does the test lamp turn ON when the TCC solenoid valve is commanded ON, and OFF when commanded OFF? | -- | |||||||||||
6 | Is the test lamp always ON? | -- | ||||||||||
Refer to Automatic Transmission Inline Harness Connector End View . Is the resistance within the specified range? | 21-33 ohms | |||||||||||
8 |
Are both readings greater than the specified value? | 250 K ohms | Go to Diagnostic Aids | |||||||||
9 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics in Wiring Systems for complete circuit distribution. Refer to Circuit Testing in Wiring Systems. Refer to Wiring Repairs in Wiring Systems. Did you find a short to ground? | -- | ||||||||||
10 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics in Wiring Systems for complete circuit distribution. Inspect circuit 839 (RED) of the AT wiring harness assembly for a short to ground. Refer to Circuit Testing in Wiring Systems. Did you find a short to ground? | -- | ||||||||||
11 |
Is the replacement complete? | -- | -- | |||||||||
12 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics in Wiring Systems for complete circuit distribution. Repair the open in ignition feed circuit 1020 (PNK) to the TCC solenoid valve. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||||||
13 |
Refer to Circuit Testing in Wiring Systems. Refer to Wiring Repairs in Wiring Systems. Did you find a short to ground? | -- | ||||||||||
14 |
Refer to Circuit Testing in Wiring Systems. Refer to Wiring Repairs in Wiring Repairs. Did you find an open or short to power? | -- | ||||||||||
15 | Replace the AT wiring harness assembly (this includes the TCC solenoid valve). Refer to Valve Body . Is the replacement complete? | -- | -- | |||||||||
16 | Replace the VCM. Refer to VCM Replacement/Programming in Engine Controls. Is the replacement complete? | -- | -- | |||||||||
17 | Perform the following procedure in order to verify the repair:
Has the test run and passed? | -- | System OK |