Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Perform an accuracy test of the J 44175 Fuel Composition Tester.
Is the reading within 6 Hz of the specification? | 136 Hz | Go to Step 2 | Go to Step 7 |
2 |
Important: Drain the acetone completely from the tester. Clean the beaker with a clean dry paper towel before taking a fuel sample. Be careful not to allow fingerprints, sweat, water or any other outside debris contaminate the fuel sample, beaker, tester or fuel gauge as this will cause an error in the test result, leading to a misdiagnosis.
Is the green LED ON? | -- | Go to Step 4 | Go to Step 3 |
3 | Is the red LED ON? | -- | Go to Step 5 | Go to Step 7 |
4 |
Is the reading from the scan tool and the DVM within the specified amount? | 12 Hz | System OK | Go to Step 6 |
5 |
Is the action complete? | -- | System OK | -- |
6 | Replace the fuel composition sensor. Refer to Fuel Composition Sensor Replacement . Is the action complete? | -- | System OK | -- |
7 | Replace the 9-volt battery and retest. If the result is the same, the tester will need to be sent out for repair. | -- | -- | -- |