This vehicle is equipped with an on-board diagnostic display feature capable of displaying diagnostic trouble codes using the 3 indicators on the rear parking assist display. After the bulb check has been completed, the red outside indicator flashes to indicate a malfunction with the system. The module disables operation of the URPA system under this condition.
In order to enter the diagnostic mode, complete the following actions:
If the vehicle is not shifted into reverse within 5 seconds after turning the ignition ON, the diagnostic mode will still be initiated. However, a reverse input wiring fault will be registered as sequence #7 as shown in the Diagnostic Indicator table below. Refer to Diagnostic Trouble Code (DTC) Clearing for the specific steps on how to clear diagnostic trouble codes. After the reverse input wiring code is cleared, repeat the diagnostic trouble code displaying steps in order to enter the diagnostic mode.
When the diagnostic mode is first entered, the rear parking assist display displays the amber outside indicator and the red outside indicator. Then, the indicators on the rear parking assist display will display one or more of the sequences in the table below to indicate where the fault exists within the rear parking assist system. Refer to Diagnostic Trouble Code (DTC) Clearing for the specific steps on how to clear diagnostic trouble codes.
# | State/Fault Location | Amber Outside | Amber Middle | Red Outside | Flashing |
---|---|---|---|---|---|
1 | Start of Diagnostics | X | -- | X | -- |
2 | RR Corner Object Sensor and Wiring | X | -- | -- | -- |
3 | RR Middle Object Sensor and Wiring | X | X | -- | -- |
4 | LR Middle Object Sensor and Wiring | -- | X | X | -- |
5 | LR Corner Object Sensor and Wiring | -- | -- | X | -- |
6 | Chime Warning Wiring | -- | X | -- | -- |
7 | Reverse Input Wiring | -- | X | -- | X |
8 | Sensor Supply Voltage Circuit and Sensor Low Reference Circuit Important: This diagnostic pattern sets for an open sensor supply voltage circuit and sensor low reference circuit. | X | X | X | X Flashes in the following sequence:
|
9 | Sensor Supply Voltage Circuit Important: This diagnostic pattern sets for a short to ground in the sensor supply voltage circuit. | X | X | X | -- |