Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Park brake set with ignition switch ON | |||
Battery Voltage | Data Display | Volts | 12-14.7 |
Left Rear Position Sensor Signal | Data Display | Volts | 0.5-4.85 |
Left Front Position Sensor Signal | Data Display | Volts | 0.5-4.85 |
Right Front Position Sensor Signal | Data Display | Volts | 0.5-4.85 |
Right Rear Position Sensor Signal | Data Display | Volts | 0.5-4.85 |
Left Rear Damper Actuator Command | Data Display | % | Varies |
Left Front Damper Actuator Command | Data Display | % | Varies |
Right Front Damper Actuator Command | Data Display | % | Varies |
Right Rear Damper Actuator Command | Data Display | % | Varies |
Vehicle Speed | Data Display | Km/h/mph | Varies |