The stop lamp switch is used to sense the action of the driver application of the brake pedal. The stop lamp switch is a normally open switch that, when applied, provides a B+ analog voltage to the transmission control module (TCM).
When the TCM detects an open stop lamp switch circuit, 0-volts, during a calibrated number of decelerations, then DTC P0719 sets. DTC P0719 is a type C DTC.
This diagnostic procedure supports the following DTC:
DTC P0719 Brake Switch Circuit Low Voltage
• | No OSS DTCs P0722 or P0723. |
• | Brake Switch DTC P0724 has not passed. |
• | The TCM detects the brake switch is apply for 900 seconds. |
• | The vehicle speed is less than 8 km/h (5 mph) for greater than 6 seconds, then greater than 40 km/h (25 mph) for 6 seconds. |
• | Continuously 8 times once the previous criteria have been met. |
• | This DTC has not passed this ignition cycle. |
The TCM detects an open or short to ground on the stop lamp switch signal circuit during 8 consecutive vehicle accelerations.
• | The TCM does not request the engine control module (ECM) to illuminate the malfunction indicator lamp (MIL). |
• | The TCM records the operating conditions when the Conditions for Setting the DTC are met. The TCM records this information as a Failure Record. |
• | The TCM stores DTC P0719 in TCM history. |
• | The TCM clears the DTC from TCM history if the vehicle completes 40 warm-up cycles without a non-emission related diagnostic fault occurring. |
• | A scan tool can clear the DTC. |
• | Inspect the brake switch for proper mounting and operation. |
• | Inspect for ABS DTCs. A faulty ABS condition may contribute to setting DTC P0719. |
• | It may be necessary to also clear this DTC from the ECM. |
The numbers below refer to the step numbers on the diagnostic table.
Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Important: Before clearing the DTC, use the scan tool in order to record the Failure Records. Using the Clear Info function erases the Failure Records from the TCM. Caution: Refer to SIR Caution in the Preface section. Does the test lamp illuminate? | Go to Step 3 | Go to Step 4 |
Connect a fused jumper wire between the ignition voltage supply and signal circuits of the stop lamp switch connector. Did the Brake Switch status on the scan tool change from Open to Closed? | Go to Step 7 | Go to Step 9 | |
4 | Inspect the ignition voltage supply fuse for an open. Refer to Circuit Protection - Fuses . Is the fuse open? | Go to Step 5 | Go to Step 8 |
5 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics for complete circuit distribution. Test the ignition voltage circuit of the brake switch for a short to ground. Refer to Testing for Short to Ground and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 6 |
6 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics for complete circuit distribution. Test the signal circuit of the brake switch for a short to ground. Refer to Testing for Short to Ground and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
7 | Replace the brake switch. Refer to Stop Lamp Switch Replacement . Did you complete the replacement? | Go to Step 11 | -- |
8 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics for complete circuit distribution. Test the ignition voltage circuit of the brake switch for an open. Refer to Testing for Continuity and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | -- |
9 |
Important: The condition that affects this circuit may exist in other connecting branches of the circuit. Refer to Power Distribution Schematics for complete circuit distribution. Test the signal circuit of the brake switch for an open. Refer to Testing for Continuity and Wiring Repairs . Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
10 | Replace the TCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 11 | -- |
11 | Perform the following procedure in order to verify the repair:
Has the test run and passed? | Go to Step 12 | Go to Step 2 |
12 | With the scan tool, observe the stored information, capture info, and DTC Info. Does the scan tool display any DTCs that you have not diagnosed? | System OK |