- Install a NEW exhaust manifold pipe seal to the exhaust manifold pipe.
- Install the exhaust manifold pipe.
- Using the transmission jack, raise the transmission.
Notice: Refer to Fastener Notice in the Preface section.
- Install the exhaust manifold pipe nuts.
Tighten
Tighten the nuts to 50 N·m (39 lb ft).
- If the old oxygen sensor is being reused, apply anti-seize compound GM P/N 12377953
or equivalent to the threads.
- Install the oxygen sensor.
Tighten
Tighten the sensor to 42 N·m (31 lb ft).
- Connect the oxygen sensor electrical connector.
- Connect the CPA retainer.
- Install the clip around the engine harness and the oxygen sensor pigtail.
- Install the exhaust pipe/catalytic converter to the vehicle.
- Install the exhaust system hangers.
- Depending on which side is being replaced, perform one of the following steps:
• | Install the exhaust muffler nuts. |
Tighten
Tighten the nuts to 40 N·m (30 lb ft).
• | Install a NEW exhaust pipe clamp. |
Tighten
Tighten the clamp to 44 N·m (33 lb ft).
- Install the transmission support crossmember.
- Install the transmission support crossmember bolts.
Tighten
Tighten the bolts to 95 N·m (70 lb ft).
- Lower the transmission onto the transmission support.
- Install the transmission mount to transmission support nuts.
Tighten
Tighten the nuts to 40 N·m (30 lb ft).
- Remove the transmission jack.
- Lower the vehicle.