• | The condition may be intermittent. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
• | The air temperature actuators can be calibrated. Refer to Actuator Recalibration . |
The numbers below refer to the step numbers on the diagnostic table.
This step ensures that the lower air temperature sensors operate properly. The LH and RH Heater Duct Actual parameter count values should lower as the air temperature of the ducts get warmer. If there is a high resistance in either of the air temperature sensors circuits or the sensor itself then the count value of the effected sensor would remain high.
This step ensures that the upper air temperature sensors operate properly. The LH and RH AC Duct Actual parameter count values should lower as the air temperature of the ducts get warmer. If there is a high resistance in either of the air temperature sensors circuits or the sensor itself, then the count value of the effected sensor would remain high.
This action ensures that the internal fan of the inside air temperature sensor assembly is providing air flow across the internal sensor.
Use the following table to determine that the recorded scan tool values are within range for the recorded probe temperatures.
Temperature °C | Temperature °F | Scan Tool Display |
---|---|---|
0-4 | 32-40 | 206-175 counts |
5-9 | 41-49 | 194-161 counts |
10-14 | 50-58 | 180-145 counts |
15-19 | 59-67 | 166-133 counts |
20-24 | 68-76 | 150-119 counts |
25-29 | 77-85 | 136-106 counts |
30-34 | 86-94 | 121-93 counts |
35-39 | 95-103 | 107-81 counts |
40-44 | 104-112 | 94-69 counts |
45-49 | 113-121 | 83-59 counts |
50-54 | 122-130 | 72-51 counts |
55-59 | 131-139 | 63-44 counts |
60-64 | 140-148 | 55-37 counts |
Step | Action | Values | Yes | No | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature can not be adjusted, or heating is insufficient. | ||||||||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||||||||||
2 |
Important: If during this diagnostic procedure the HVAC control module is disconnected, a recalibration of actuators must be performed to avoid misdiagnosis.
Does the scan tool display any DTC B0229, B0414, B0424 or B3770? | -- | Go to Diagnostic Trouble Code (DTC) List - Vehicle in Vehicle DTC Information | Go to Step 3 | ||||||||||||||||
3 |
Does the blower motor operate in any of the speed positions speed? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||||||||
4 | Does the blower motor operate in all desired speed positions? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||||||||
5 |
Does the recirculation door move from the recirculation position to the outside air position? | -- | Go to Step 6 | |||||||||||||||||
6 |
Does the A/C compressor clutch disengage? | -- | Go to Step 7 | |||||||||||||||||
7 | Perform the Heating Performance Diagnostic. Refer to Heating Performance Diagnostic . Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 8 | ||||||||||||||||
Do both of the Heater Duct Actual parameter values increase within 15 counts of the Heater Duct Desired parameter? | -- | Go to Step 9 | Go to Step 20 | |||||||||||||||||
Do both of the AC Duct Actual parameter values increase within 15 counts of the AC Duct Desired parameter? | -- | Go to Step 10 | Go to Step 20 | |||||||||||||||||
10 | Check the air temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 11 | ||||||||||||||||
Does the paper stay in place? | -- | Go to Step 13 | Go to Step 12 | |||||||||||||||||
12 |
Does the test lamp illuminate? | -- | Go to Step 18 | Go to Step 17 | ||||||||||||||||
13 |
Does the scan tool indicate that the Left Solar Sensor and Right Solar Sensor parameters are greater than the specified value? | 220 Counts | Go to Step 14 | Go to Step 23 | ||||||||||||||||
14 |
Does the scan tool indicate that the Inside Air Temp parameter is within 3°C (5°F) of the probe temperature? | -- | Go to Step 15 | Go to Step 19 | ||||||||||||||||
Are the parameter values within the specified range for the recorded air temperatures? | -- | Go to Diagnostic Aids | Go to Step 16 | |||||||||||||||||
16 |
Does the resistance measure near the specified range? | -- | Go to Step 24 | Go to Step 20 | ||||||||||||||||
17 | Test the inside air temperature sensor assembly control circuit of the inside air temperature sensor assembly for an open, a high resistance, or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 24 | ||||||||||||||||
18 | Test the ground circuit of the inside air temperature sensor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 22 | ||||||||||||||||
19 |
Does the resistance measure within the specified range? | -- | Go to Step 24 | Go to Step 20 | ||||||||||||||||
20 | Test the signal circuit of the suspect air temperature sensor for a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 21 | ||||||||||||||||
21 | Test the low reference circuit of the suspect air temperature sensor for a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 22 | ||||||||||||||||
22 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 25 | ||||||||||||||||
23 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 26 | ||||||||||||||||
24 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 28 | Go to Step 27 | ||||||||||||||||
25 | Replace the suspect air temperature sensor. Refer to one of the following procedures: Did you complete the replacement? | -- | Go to Step 28 | -- | ||||||||||||||||
26 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? | -- | Go to Step 28 | -- | ||||||||||||||||
27 | Replace the HVAC control module. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 28 | -- | ||||||||||||||||
28 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |