Blower Motor Replacement Delphi
Removal Procedure
- If
equipped, remove the sound insulator panel. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages,
and Console.
- Remove the blower motor insulating cover screws.
- Disconnect the electrical connector from the blower motor.
- Remove the blower motor insulating cover.
- Pull
the retaining tab down while turning the blower motor counterclockwise
in order to disengage the blower motor from the heater/ventilation module.
- Remove
the blower motor.
Installation Procedure
- Install
the blower motor.
- Install
the blower motor to the heater/ventilation module. Turn the blower assembly clockwise
until the retaining tab locks into place.
- Install the blower motor insulating cover.
- Connect
the electrical connector to the blower motor.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower motor insulating cover screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- If equipped, install the sound insulator panel. Refer to
Instrument Panel Insulator Replacement
in Instrument
Panel, Gages, and Console.
Blower Motor Replacement Visteon
Removal Procedure
- Remove the sound insulator panel. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages, and
Console.
- Disconnect the electrical connector (2) from the blower motor (1).
- Remove the screws from the blower motor (1).
- Remove the blower motor (1) from the HVAC module (3).
- Remove the retainer from the blower motor wheel.
Discard the
retainer.
- Remove the blower motor wheel from the blower motor (1).
Installation Procedure
- Install the blower motor wheel to the blower motor (1).
- Install the New retainer to the blower motor wheel.
- Install the blower motor (1) to the HVAC module (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the blower motor (1).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector (2) to the blower motor (1).
- Install the sound insulator panel. Refer to
Instrument Panel Insulator Replacement
in Instrument Panel, Gages,
and Console .