• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Control | P0615 | P0615 | P0615 | -- |
Ground | -- | P0615 | -- | -- |
When the ignition switch is placed in the start position, a discrete signal is supplied to the body control module (BCM) notifying it that the ignition is in the start position. The BCM sends a serial data message to the engine control module (ECM) that crank has been requested. The ECM then verifies that the automatic transmission is in Park or Neutral, and that the immobilizer is not disabling engine starting. If conditions are acceptable for cranking, then the ECM supplies 12 V to the control circuit of the STRTR relay. When this occurs, battery voltage is supplied through the switch of the STRTR relay to terminal S X2 of the starter solenoid, and the engine cranks. The ECM monitors the voltage on the STRTR relay control circuit. If the ECM detects that the STRTR relay control circuit is open, shorted to ground, or shorted to voltage, then DTC P0615 sets.
• | The ignition is ON or in the start position. |
• | The battery voltage is 9.5-18 V. |
The ECM detects that the control circuit of the STRTR relay is open, shorted to ground, or shorted to voltage for 2 seconds.
DTC P0615 is a type C DTC.
The DTC passes when the ECM detects that the failure is no longer present for 2 seconds.
Starting and Charging Schematics
Starting System Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If any DTCs are set that would cause the ECM to disable starting, then refer to Diagnostic Trouble Code (DTC) List - Vehicle. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always on, test the control circuit for short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp is always off, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming. |