• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Headlamp LO/HID Relay B+ | 1 | 1 | -- | -- |
High Beam Relay B+ | 2 | 2 | -- | -- |
Headlamp Flash to Pass Signal | 4 | 4 | 4 | -- |
Headlamp Dimmer Switch Signal | 4 | 4 | 4 | -- |
Headlamp Low Beam Control | 1 | 1 | 1 | -- |
Headlamp Low Beam Relay Control | 1 | 1 | B2575 00 | -- |
Headlamp Switch Off Control | B257A 00 | 3 | 3 | -- |
Headlamp Switch On Control | B257A 00 | 3 | 3 | -- |
Headlamp High Beam Control | 2 | 2 | 2 | -- |
Headlamp High Beam Relay Control | 2 | 2 | B2580 00 | -- |
Park Lamp Switch On Control | B257A 00 | B257A 00 | 3 | -- |
Headlamp Switch Ground | -- | 2 | -- | -- |
Turn Signal/Multifunction Switch Malfunction | -- | 4 | -- | -- |
|
When the turn signal/multifunction switch is placed in the headlamps high or flash to pass (FTP) position, ground is applied to the body control module (BCM) through the headlamp high beam signal circuit or the flash to pass signal circuit. The BCM applies ground to the headlamp HIGH BEAM relay control circuit which energizes the HIGH BEAM relay. With the HIGH BEAM relay energized, the switch contacts close allowing B+ to flow through the HI BEAM fuses to the high beam headlamps. Ground for the left headlamp is supplied at G100 and the right headlamp receives ground at G101.
• | Battery voltage must be between 9-16 volts. |
• | Headlamps ON. |
DTC B2580 00 will set when the BCM detects a short to voltage in the headlamp HIGH BEAM relay control circuit.
When DTC B2580 00 is present, the high beam headlamps and flash to pass (FTP) will not operate.
• | The condition responsible for setting the DTC no longer exists. |
• | A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred. |
Headlights/Daytime Running Lights (DRL) Schematics
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |