Coolant Bypass Hose Replacement LH2
Removal Procedure
- Drain the cooling system. Refer to
Cooling System Draining and Filling.
- Remove the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Compress the clamp, and remove the heater outlet hose (3) from the thermostat housing in order to gain access to the bypass hose.
- Compress the clamps (1, 3) and remove the bypass hose (2) from the water outlet housing and the front cover.
Installation Procedure
- Compress the clamps (1, 3) and install the bypass hose (2) to the water outlet housing and the front cover.
- Compress the clamp, and install the heater outlet hose (3) to the thermostat housing.
- Compress the clamp, and remove the heater outlet hose (3) from the thermostat housing in order to gain access to the bypass hose.
- Install the air cleaner outlet duct. Refer to
Air Cleaner Outlet Duct Replacement.
- Fill the cooling system. Refer to
Cooling System Draining and Filling.