Starter Replacement LY7
Removal Procedure
- Turn OFF the ignition.
- Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Remove the starter solenoid electrical connector from the starter.
- Remove the starter terminal nut (1) and the battery positive cable (2) from the starter.
- Remove the starter motor bolts.
- Remove the starter motor.
Installation Procedure
- Install the starter motor.
Notice: Refer to Fastener Notice in the Preface section.
- Install the starter motor mounting bolts.
Tighten
Tighten the starter motor mounting bolts to 51N·m (38 lb ft).
- Install the battery positive cable (2) to the starter and install the starter terminal nut (1).
Tighten
Tighten the batter positive cable nut to 13N·m (115 lb in).
- Install the electrical connector to the starter solenoid.
Starter Replacement LH2
Removal Procedure
- Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.
- Remove the intake manifold. Refer to
Intake Manifold Replacement.
- Disconnect the battery positive cable (2) from the starter.
- Disconnect the wire (4) from the S terminal on the starter.
- Remove the starter motor bolts.
- Remove the starter motor.
Installation Procedure
- Install the starter motor.
Notice: Refer to Fastener Notice in the Preface section.
- Install the starter motor bolts.
Tighten
Tighten the bolt to 30 N·m (22 lb ft).
- Connect the wire (4) and nut to the S terminal on the starter.
Tighten
Tighten the nut to 4 N·m (35 lb in).
- Connect the battery positive cable (4) and nut to the starter terminal.
Tighten
Tighten the nut to 10 N·m (89 lb in).
- Install the intake manifold. Refer to
Intake Manifold Replacement.
- connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection.