Table 1: | HVAC Control Module Scan Tool Data List |
Table 2: | ECM Scan Tool Data List - 4.6L (LH2), 3.6L (LY7) |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C Clutch - Actual | A/C Compressor Data | On/Off | On |
A/C Clutch - Desired | A/C Compressor Data | Yes/No | Yes |
A/C Pressure | A/C Compressor Data | kPa/psi | Varies |
Commanded Blower | HVAC System Data | % | Varies |
Coolant Temperature | HVAC System Data | °C/°F | Varies |
Driver Temp. Dr. Actual | HVAC Door Positions | Counts/Volts | Varies |
Driver Temp. Dr. Commanded | HVAC Door Positions | Counts/Volts | Varies |
Driver Solar Sensor | Open/Short Data | Counts/Volts | Varies |
Driver Sunload | HVAC System Data | w/m2 | Varies |
Evaporator Temp | HVAC System Data | °C/°F | Varies |
Evaporator Temp | A/C Compressor Data | °C/°F | Varies |
Evaporator Temp | Open/Short Data | Counts/Volts | Varies |
Htr./Def./A/C Dr. Actual | HVAC Door Positions | Counts/Volts | Varies |
Htr./Def./A/C Dr. Commanded | HVAC Door Positions | Counts/Volts | Varies |
Inside Air Temp | HVAC System Data | °C/°F | Varies |
Inside Air Temp | Open/Short Data | Counts/Volts | Varies |
Low Coolant Status | HVAC System Data | OK/Low | OK |
Low Coolant Switch | HVAC System Data | Open/Closed | Closed |
Outside Air Temp | HVAC System Data | °C/°F | Varies |
Outside Air Temp | Open/Short Data | Counts/Volts | Varies |
Passenger Solar Sensor | Open/Short Data | Counts/Volts | Varies |
Passenger Sunload | HVAC System Data | w/m2 | Varies |
Passenger Temp Dr. Actual | HVAC Door Positions | Counts/Volts | Varies |
Passenger Temp Dr. Commanded | HVAC Door Positions | Counts/Volts | Varies |
Pressure Sensor | A/C Compressor Data | OK/Failed | OK |
Vehicle Speed | HVAC System Data | Km/h/mph | Varies |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F) | |||
A/C High Side Pressure Sensor | HVAC System Data | kPa/Psi | 629-845 kPa (85-120 psi) |
A/C High Side Pressure Sensor | HVAC System Data | V | Varies |
A/C Relay Command | HVAC System Data | On/Off | Varies |
A/C Request Signal | HVAC System Data | Yes/No | Varies |
Engine Coolant Temperature Sensor | HVAC System Data | °C/°F | Varies |
A/C Off (1-8) History Records | HVAC System Data | Reason for A/C Off | Varies |
Turning off the A/C makes the throttle fully open. | HVAC System Data | Yes/No | Varies |
A/C Pressure Disabled | HVAC System Data | Yes/No | Varies |
A/C Relay Circuit Status | HVAC System Data | OK/Uncompleted/Short to B+/Short to Ground/Open | OK |
Calculated Engine Coolant Temperature - Closed Loop Fuel Control | HVAC System Data | °C/°F | Varies |
Calculated Engine Coolant Temperature - Thermostat Diagnosis | HVAC System Data | °C/°F | Varies |
5V Reference Voltage 1 or 2 | HVAC System Data | V | 4.5 |
5V Reference Voltage 1 or 2 Circuit Status | HVAC System Data | OK/Failed | OK |
Engine Load | HVAC System Data | 0-99% | 0-5% - idle: 3-7% - 2500 RPM |
Calculated Engine Oil Temperature | HVAC System Data | °C/°F | Varies |
Engine Oil Temperature Sensor | HVAC System Data | °C/°F | Varies |
Engine Runtime | HVAC System Data | 0:00:00 | Varies |
Engine Speed | HVAC System Data | RPM | 650 RPM |
Hot Open Loop | HVAC System Data | Active/Inactive | Inactive |
Intake Air Temperature (IAT) Sensor | HVAC System Data | °C/°F | Varies |
Ignition 1 Signal | HVAC System Data | 0-25.5 V | 12.8-14.2 V |
Knock Retard | HVAC System Data | Degrees | Varies |
Spark | HVAC System Data | ° | -- |
Engine Coolant Temperature at Start | HVAC System Data | °C/°F | Varies |
Calculated Engine Coolant Temperature - Closed Loop Fuel Control | Cooling/HVAC System Data | °C/°F | Varies |
Calculated Engine Coolant Temperature - Thermostat Diagnosis | Cooling/HVAC System Data | °C/°F | Varies |
Intake Air Temperature | HVAC System Data | °C/°F | Varies |
Transmission Oil Temperature Sensor | HVAC System Data | °C/°F | Varies |
Total Knock Retard | HVAC System Data | ° | 0 |
Vehicle Speed Sensor | HVAC System Data | Km/Mile | Varies |
Capacity Efficiency | Cooling/HVAC System Data | 0-100% | 5-25% - idle and 2,500 RPM |