Caution: When performing service on or near the SIR components or the SIR wiring, the SIR system must be disabled. Refer to SIR Disabling and Enabling .
Failure to observe the correct procedure could cause deployment of the SIR components, personal injury, or unnecessary SIR system repairs.
|
|
Important:
• | To avoid accidental deployment of the airbags, the shorting bars close in order to short the connectors when the connectors are separated. |
• | Twisted-pair wires provide an effective shield that helps protect sensitive electronic components from electrical interference. If the wires were covered with shielding, install new shielding. |
• | In order to prevent electrical interference from degrading the performance of the connected components, you must maintain the proper specification when making any repairs to the twisted-pair wires shown : |
- | The wires must be twisted a minimum of 9 turns per 31 cm (12 in) as measured anywhere along the length of the wires |
- | The outside diameter of the twisted wires must not exceed 6.0 mm (0.25 in) |
|