Exhaust Manifold Replacement - Right Side LY7
Removal Procedure
Caution: Refer to Exhaust Service Caution in the Preface section.
Caution: Refer to Protective Goggles and Glove Caution in the Preface section.
- Remove the exhaust manifold heat shield. Refer to
Exhaust Manifold Heat Shield Replacement - Right Side.
- Remove the catalytic converter nuts.
- Remove the exhaust manifold bolts.
Important: Do not reuse the gasket.
- Remove the exhaust manifold and discard the exhaust manifold gasket.
- Clean and inspect the exhaust manifold. Refer to
Exhaust Manifold Cleaning and Inspection - Left Side.
Installation Procedure
Important: Inspect the catalytic converter seal/heat shield sealing surface. Replace the seal/heat shield if the sealing surface is worn or damaged.
- Install the catalytic converter seal/heat shield to the catalytic converter.
- Install a new exhaust manifold gasket to the exhaust manifold.
- Install the exhaust manifold with the gasket to the catalytic converter and the cylinder head.
Notice: Refer to Fastener Notice in the Preface section.
- Install the exhaust manifold bolts.
Tighten
Tighten the exhaust manifold bolts to 20 N·m (15 lb ft).
- Install the catalytic converter nuts.
Tighten
Tighten the catalytic converter nuts to 50 N·m (37 lb ft).
- Install the exhaust manifold heat shield. Refer to
Exhaust Manifold Heat Shield Replacement - Right Side.
Exhaust Manifold Replacement - Right Side LH2
Removal Procedure
Caution: Refer to Exhaust Service Caution in the Preface section.
Caution: Refer to Protective Goggles and Glove Caution in the Preface section.
- Disconnect the right heated oxygen sensor pigtail from the wiring harness connector.
- Remove the right exhaust manifold heat shield.
- Remove the heated oxygen sensor, if necessary. Refer to
Heated Oxygen Sensor Replacement - Bank 1 Sensor 1.
- Remove the right exhaust manifold bolts and nuts. Discard the exhaust manifold bolts.
- Remove the exhaust manifold studs, if necessary.
- Remove the right exhaust manifold and gasket from the engine. Do not reuse the gasket.
- Clean and inspect the right exhaust manifold. Refer to
Exhaust Manifold Cleaning and Inspection - Right Side.
Installation Procedure
- Use a new exhaust manifold gasket over the cylinder head studs.
- Position the right exhaust manifold and gasket to the right cylinder head.
Notice: Refer to Fastener Notice in the Preface section.
- Install the right exhaust manifold studs, nuts and new bolts.
Tighten
• | Tighten the exhaust manifold studs to 6 N·m (53 lb in). |
• | Tighten the exhaust manifold nuts to 30 N·m (22 lb ft). |
• | Tighten the exhaust manifold bolts to 25 N·m (18 lb ft). |
- Install the heated oxygen sensor if previously removed. Refer to
Heated Oxygen Sensor Replacement - Bank 1 Sensor 1.
- Install the exhaust manifold heat shield.
- Connect the heated oxygen sensor pigtail to the wiring harness connector.