- Cycle the sunroof window from the full open to the full closed position.
Note: Correct adjustment cannot be achieved if the sunroof window is closed from the vent position.
- Fully cycle and close the sunroof window.
- Disconnect the top side of the sunroof panel side opening closeout panel covers (5) from the 3 clips located on the inner edge of the sunroof window (1,3,4) in order to access the window adjustment screws (2,6).
- Tape the side opening closeout panels in a downward position prior to adjusting the window.
- Loosen the 2 adjusting screws (1) on each side of the sunroof window.
- Center the window front to rear in the opening.
Caution: Refer to Fastener Caution in the Preface section.
- Adjust the front of the sunroof window (2) from flush to 1 mm (0.04 in) (1) below the top surface of the roof panel (3).
Tighten
Tighten the adjustment screws to 4.5 N·m (40 lb in).
- Adjust the rear of the sunroof window (2) from flush to 1 mm (0.04 in) above the top surface of the roof panel (1).
Tighten
Tighten the adjustment screws to 4.5 N·m (40 lb in).
- Remove the tape from the sunroof panel side opening closeout covers (2).
- Connect the side opening closeout panel covers (5) to both sides of the sunroof window clips (1,3,4).
- Cycle the sunroof window through all of the positions.
- Verify the sunroof window fore/aft adjustment.
- Verify the front and rear height adjustment.
- Readjust the sunroof window, if necessary.