Auxiliary Water Pump Replacement 4.6L (LH2) w/RPOs V03/V92
Tools Required
J 38185
Hose Clamp Pliers
Removal Procedure
- Drain the coolant. Refer to
Cooling System Draining and Filling
.
- Using the
J 38185
slide the hose clamp down on the hose (3).
- Disconnect the hose from the auxiliary water pump.
- Using the
J 38185
slide the hose clamp back on the hose (1).
- Disconnect the hose from the auxiliary water pump.
- Disconnect the auxiliary water pump electrical connector.
- Remove the auxiliary water pump nuts.
- Remove the auxiliary water pump.
Installation Procedure
- Install the auxiliary water pump.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the auxiliary water pump nuts.
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Connect the auxiliary water pump electrical connector.
- Connect the hose (3) to the auxiliary water pump.
- Using the
J 38185
slide the hose clamp back into the original position on the hose.
- Connect the hose (1) to the auxiliary water pump.
- Using the
J 38185
slide the hose clamp back to the original position on the hose.
- Fill the coolant. Refer to
Cooling System Draining and Filling
.