Cleaning Procedure
- Clean the oil pump outlet with solvent.
Caution: Refer to Safety Glasses Caution in the Preface section.
- Dry the oil pump outlet tube with compressed air.
Inspection Procedure
- Inspect the mounting surfaces (1) for possible leakage paths.
- Inspect the oil pump outlet tube pipe (2) for cracks, imperfections and/or damage.
- Inspect the oil pump outlet tube for distortion or damage to the pipe (3) and the bracket at the oil pump outlet end.
- Repair or replace the oil pump outlet tube as necessary.