Caution: Refer to Battery Disconnect Caution in the Preface section.
Caution: The high intensity discharge system produces high voltage and current.
To reduce the risk of severe shocks and burns:
• Never open the high intensity discharge system ballast or the
arc tube assembly starter. • Never probe between the high intensity discharge system ballast
output connector and the arc tube assembly.
Caution: The high intensity discharge system produces high voltage and current. In order to reduce the risk of severe shocks and burns, the battery negative cable must be disconnected any time service work is being performed on or around the high intensity discharge system.
Important: Be careful when disconnecting the electrical connectors.
Notice: Refer to Fastener Notice in the Preface section.
Important: Always replace the old gasket with the gasket provided with the new ballast .
Tighten
Tighten the ballast screws (1) to 2 N·m (18 lb in).