• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Liftgate Module B+ | B153A 08, B396A 02 | B153A 08, B396A 02 | -- | -- |
Liftgate Module B+ | U0230 00 | U0230 00 | -- | -- |
Liftgate Position Sensor 5V Reference Voltage | B153E 02 | B153B 08 | 2 | B1019 00 |
Full Open Signal | B153E 08 | B153B 05 | 2 | -- |
Object Sensors Signal | B153F 02 | B153F 05 | B153F 05 | B153F 03, B153F 07 |
Open/Close Switches Signal | B2494 02 | 1, 2 | 1, 2 | -- |
Pawl Switch Signal | B153A 00 | B153A 08 | B153A 00 | B153A 08 |
Position Sensor Signal 1 | B153E 08 | B153E 08 | B153E 05 | -- |
Position Sensor Signal 2 | B153E 08 | B153A 08 | B153E 05 | B153E 08 |
Ratchet Switch Signal | B153A 00 | B153A 08 | B153A 00 | B153A 08 |
Sector Switch Signal | B153A 00 | B153A 00 | B153A 00 | B153A 08 |
Disengage Clutch Control | B396B 02 | B396B 04 | B396B 01 | -- |
Engage Clutch Control | B396B 02 | B396B 04 | B396B 01 | -- |
Liftgate Latch Cinch Control | B2495 02 | B2495 04 | B2495 01 | -- |
Liftgate Latch Release Control | B2495 02 | B2495 04 | B2495 01 | -- |
Liftgate Motor Close Control | B396A 02 | B396A 04 | B396A 01 | B153E 08 |
Liftgate Motor Open Control | B396A 02 | B396A 04 | B396A 01 | B153E 08 |
Full Open Low Reference | -- | B153B 05 | 2 | -- |
Liftgate Switches Low Reference | -- | B153A 08 | 1 | B153E 08 |
Position Sensor Low Reference | -- | B153E 08 | 2 | -- |
Liftgate Control Module Ground | -- | U0230 00 | 2 | -- |
1. Liftgate Switch Malfunction 2. Liftgate Malfunction |
The liftgate control module (LGM) continuously monitors power liftgate operation and calculates its location and direction of travel using 2 Hall effect sensors that are part of the gear motor assembly. The Hall effect sensors are 5-volt 3-wire sensors and are supplied with a 5-volt power, ground and signal circuits from the LGM. The Hall effect sensor signal circuits are referenced from voltage within the LGM and pulsed low by the Hall effect sensors.
The system voltage is 9-16 volts.
The LGM detects a short to ground in the liftgate motor assembly position sensor circuit.
The LGM detects a short to voltage or an open/high resistance in the liftgate motor assembly position sensor circuit.
The LGM does not detect optical sensor pulses when the liftgate is in motion.
The power liftgate system will be disabled.
• | The DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will be a history DTC. |
• | A history DTC will clear after 50 ignition cycles. |
Whenever the LGM loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the LGM.
Liftgate Description and Operation
Control Module References for scan tool information
⇒ | If not the specified range, replace the LGM. |
⇒ | If greater than the specified value, replace the LGM. |
⇒ | If not within the specified range, replace the LGM. |
⇒ | If not within the specified range, replace the LGM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for LGM replacement, setup and programming