Diagnostic Instructions
DTC Descriptor
DTC B1428 00: Ignition Switched Power Relay 1 Circuit
Circuit/System Description
The body control module (BCM) controls the IGN MAIN relay by applying voltage to the circuit. The IGN MAIN relay is energized when the ignition switch is in RUN or START, or when a remote start is requested.
Conditions for Running the DTC
• | The system voltage is between 9-16 V. |
• | The DTC can only run when the output is activated. |
Conditions for Setting the DTC
DTC will set when the output is activated and there is a short to ground in the circuit.
Action Taken When the DTC Sets
The module output driver will be shut down and not supply voltage to the run/crank ignition 1 voltage circuit
Conditions for Clearing the DTC
• | The current DTC will clear when the module request for the output is removed or the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the reset threshold of 50, without a repeat of the malfunction. |
Reference Information
Schematic Reference
Connector End View Reference
Component Connector End Views
Description and Operation
Retained Accessory Power Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information.
Circuit/System Testing
- Ignition OFF, disconnect the IGN MAIN relay.
- Connect a test lamp between the relay control circuit and ground.
- Cycle the ignition ON and OFF. The test lamp should turn ON and OFF when changing ignition switch positions.
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
- If all circuits test normal, test or replace the IGN MAIN relay.
Component Testing
- Ignition OFF, disconnect the IGN MAIN relay.
- Test for 70-150 Ω of resistance between terminals 85 and 86.
⇒ | If the resistance is not within the specified range, replace the relay. |
- Test for infinite resistance between the following terminals:
- Test for less then 2 Ω of resistance between terminals 30 and 87A.
⇒ | If greater then the specified range, replace the relay. |
- Install a 3 A fused jumper wire between relay terminal 85 and B+. Install a jumper wire between relay terminal 86 and ground. Measure for less than 2 Ω of resistance between terminals 30 and 87.
⇒ | If greater than 2 Ω, replace the relay. |