• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Fuel Level Sensor 1 Signal | P0462 | 1 | P0463 | P0463 | P0461 |
Fuel Level Sensor 2 Signal | P2067 | 1 | P2068 | P2068 | P2066 |
Fuel Level Sensor Low Reference | -- | 1 | P0463 P2068 | P0463 P2068 | P0461 P2066 |
1. Fuel Gage Inaccurate or Inoperative |
The primary fuel level sender and the secondary fuel level sender changes resistance based on fuel level. The engine control module (ECM) monitors the signal circuits of the primary fuel level sender and the secondary fuel level sender in order to determine the fuel level. When the fuel tank is full, the resistances of both fuel level senders are low and the ECM senses a low signal voltage on both the signal circuits of the primary fuel level sender and the secondary fuel level sender. When the fuel tanks are empty, the resistances of the fuel level senders are high and the ECM senses a high signal voltage. The ECM uses the signal circuits of the primary fuel level sender and the secondary fuel level sender in order to calculate the percentage of remaining fuel in the tank. The ECM sends the fuel level percentage via serial data circuit to the instrument cluster in order to control the fuel gage.
• | The engine is running. |
• | No fuel level sensor signal failure present. |
• | The fuel level state is stable. |
• | The ECM detects a difference between the engine consumed fuel and change of the fuel level signal of less than 1 L (0.26 gallons) over a range of 30 L (7.92 gallons) or 45.6 percent of the secondary fuel tank. |
• | The above condition is present for about 300 seconds. |
• | The fuel gage defaults to empty. |
• | The low fuel indicator illuminates. |
• | The ECM records the operating conditions at the time that the diagnostic test fails. The ECM displays the failure information in the Failure Records on the scan tool. |
• | The DTC becomes history when the conditions for setting the DTC are no longer present. |
• | The history DTC clears after 40 malfunction-free warm-up cycles. |
A partially filled fuel tank and filling the fuel tank with the ignition ON or engine RUNNING may cause an inaccurate or erratic fuel gage. This condition may cause a fuel system DTC to set and the fuel gage to default to empty. Refer to Fuel Gage Description and Operation.
Fuel Gage Description and Operation
Control Module References for scan tool information
⇒ | If any interference is present, repair the fuel sender interference. |
⇒ | If not within the specified range, replace the fuel level sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Secondary Fuel Tank Module Replacement for the 4.6L engine |
• | Secondary Fuel Tank Module Replacement for the 3.6L engine |
• | Control Module References for the ECM replacement, setup, and programming |