J 38185 Hose Clamp Pliers
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the nut to 9 N·m (80 lb in).
Tighten
Tighten the bolt to 9 N·m (80 lb in).
Important: Lubricate the inside diameters of the hoses with clean coolant prior to installation.
Callout | Component Name |
---|---|
Preliminary Procedures
| |
1 | Surge Tank Mounting Nut (Qty: 1) Notice: Refer to Fastener Notice in the Preface section. Tighten |
2 | Surge Tank Mounting Bolt (Qty: 1) Tighten |
3 | Surge Tank |