Table 1: | Instrument Panel Cluster Scan Tool Data Parameters |
Table 2: | Instrument Panel Cluster Scan Tool Output Controls |
Parameter | System State | Expected Value | Definition |
---|---|---|---|
Operating Conditions: Ignition ON | |||
Battery Voltage | -- | Varies | This displays volts. The scan tool displays the system voltage of the vehicle. |
Brake Fluid | -- | OK | The scan tool displays OK or Low. This is the state of the brake fluid level. |
Brake Fluid Switch | -- | Varies | This displays volts. This is the voltage status of the brake fluid switch. |
DIC Fuel Info. | -- | Inactive | The scan tool displays Active or Inactive. This is the state of the DIC Fuel Info. switch. |
DIC Information Switch | -- | Inactive | The scan tool displays Active or Inactive. This is the state of the DIC Information switch. |
DIC Personalization | -- | Off | The scan tool displays Active or Inactive. This is the status of the driver information center (DIC) personalization functions as monitored by the IPC. |
Heated Washer Fluid Ind. Signal | -- | Inactive | The scan tool displays Active or Inactive. This is the status of the heated washer fluid indicator signal as monitored by the IPC. |
Ignition 1 Input | -- | Active | The scan tool displays Active or Inactive. This is the state of the Ignition 1 input to the IPC. |
Ignition Cycle Counter | -- | Varies | The scan tool displays counts. This is the number of times the ignition has been cycled from the OFF to ON position. |
Passenger Seatbelt Indicator Commanded | -- | Off | This displays On or Off. This is the state of the seatbelt indicator command as monitored by the IPC. |
Passenger Seatbelt Indicator Status | -- | Off | This displays On or Off. This is the status of the seatbelt indicator status as monitored by the IPC. |
Trip Reset Switch | -- | Inactive | The scan tool displays Active or Inactive. This is the state of the trip reset switch. |
Washer Fluid Level | -- | OK | The scan tool displays OK or Low. This is the state of the washer fluid level. |
Scan Tool Output Control | Description |
---|---|
Dimming | The IPC increases or decreases the dimming intensity in increments of 20 percent between a range of 0-100 percent. |
Display Test | The IPC illuminates all of the indicators for 7 seconds when you select ON. |
Display(s) Test | The instrument panel cluster (IPC) drives all of the gages at or below minimum for a few seconds when you select ON, then drives all of the gages at or above maximum for a few seconds. The IPC Display Test will end after one cycle of the gages sweep. |