GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B396A 01: Liftgate Motor Control Circuit Short to Battery

DTC B396A 02: Liftgate Motor Control Circuit Short to Ground

DTC B396A 04: Liftgate Motor Control Circuit Open

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Liftgate Module B+

B153A 08, B396A 02

B153A 08, B396A 02

--

--

Liftgate Module B+

U0230 00

U0230 00

--

--

Liftgate Position Sensor 5V Reference Voltage

B153E 02

B153B 08

2

B1019 00

Full Open Signal

B153E 08

B153B 05

2

--

Object Sensors Signal

B153F 02

B153F 05

B153F 05

B153F 03, B153F 07

Open/Close Switches Signal

B2494 02

1, 2

1, 2

--

Pawl Switch Signal

B153A 00

B153A 08

B153A 00

B153A 08

Position Sensor Signal 1

B153E 08

B153E 08

B153E 05

--

Position Sensor Signal 2

B153E 08

B153A 08

B153E 05

B153E 08

Ratchet Switch Signal

B153A 00

B153A 08

B153A 00

B153A 08

Sector Switch Signal

B153A 00

B153A 00

B153A 00

B153A 08

Disengage Clutch Control

B396B 02

B396B 04

B396B 01

--

Engage Clutch Control

B396B 02

B396B 04

B396B 01

--

Liftgate Latch Cinch Control

B2495 02

B2495 04

B2495 01

--

Liftgate Latch Release Control

B2495 02

B2495 04

B2495 01

--

Liftgate Motor Close Control

B396A 02

B396A 04

B396A 01

B153E 08

Liftgate Motor Open Control

B396A 02

B396A 04

B396A 01

B153E 08

Full Open Low Reference

--

B153B 05

2

--

Liftgate Switches Low Reference

--

B153A 08

1

B153E 08

Position Sensor Low Reference

--

B153E 08

2

--

Liftgate Control Module Ground

--

U0230 00

2

--

1. Liftgate Switch Malfunction

2. Liftgate Malfunction

Circuit/System Description

The liftgate motor is a bi-directional motor and open or close operation is the result of the direction of the motor rotation. The liftgate control module (LGM) controls the liftgate motor through the control circuits by supplying power and ground in the appropriate polarity. The motor control circuits are monitored by the LGM prior to activation for a high or low condition and during motor operation for any irregular current flow conditions.

Conditions for Running the DTC

    • The system voltage is 9-16 volts.
    • Power open or close function is initiated.

Conditions for Setting the DTC

B396A 01

The LGM detects a short to voltage in the liftgate motor control circuits.

B396A 02

A loss of B+ voltage to the LGM or the LGM detects a short to ground in the liftgate motor control circuits.

B396A 04

The LGM detects an open/high resistance in the liftgate motor control circuits.

Action Taken When the DTC Sets

Power liftgate operation will be suspended.

Conditions for Clearing the DTC

    • The DTC will be current for as long as the fault is present.
    • When the fault is no longer present, the DTC will be a history DTC.
    • A history DTC will clear after 50 ignition cycles.

Diagnostic Aids

Whenever the LGM loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the LGM.

In some circumstances high or low control circuit faults may cause the LGM to react as if the liftgate has encountered an object in its travel and reverse direction.

Reference Information

Schematic Reference

Liftgate Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Liftgate Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification

  1. Ignition ON, doors unlocked, transaxle in Park, open the liftgate by pressing the touchpad on the liftgate handle switch. The liftgate should release and power open.
  2. Close the liftgate by pressing the liftgate button switch. The liftgate should power close, cinch-in, and latch.

Circuit/System Testing

  1. Ignition OFF, disconnect the X2 harness connector at the LGM.
  2. Test for less than 1 ohm between the ground circuit terminal 6 and ground.
  3. If greater than the specified range, test the ground circuit for an open/high resistance.
  4. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 3 and ground.
  5. If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, replace the LGM.
  6. Ignition OFF, connect the X2 harness connector and disconnect the X3 harness connector at the LGM.
  7. Test for less than 15 ohms between the control terminal 1 at the LGM and ground.
  8. If greater than the specified range, replace the LGM.
  9. Test for less than 15 ohms between the control terminal 2 at the LGM and ground.
  10. If greater than the specified range, replace the LGM
  11. Install a 15A fused jumper wire between the control circuit terminal 1 at the liftgate motor assembly and 12 volts. Momentarily install a jumper wire between the control circuit terminal 2 at the liftgate motor assembly and ground. The liftgate motor should perform the OPEN or CLOSE function.
  12. If the function does not perform as specified, replace the liftgate motor assembly.
  13. Install a 15A fused jumper wire between the control circuit terminal 2 and 12 volts. Momentarily install a jumper wire between the control circuit terminal 1 and ground. The liftgate motor should perform the CLOSE or OPEN function.
  14. If the function does not perform as specified, replace the liftgate motor assembly.
  15. If all circuits test normal, replace the LGM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Liftgate Close Actuator Motor Replacement
    •  Control Module References for LGM replacement, setup, and programming