• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Liftgate Module B+ | B153A 08, B396A 02 | B153A 08, B396A 02 | -- | -- |
Liftgate Module B+ | U0230 00 | U0230 00 | -- | -- |
Liftgate Position Sensor 5V Reference Voltage | B153E 02 | B153B 08 | 2 | B1019 00 |
Full Open Signal | B153E 08 | B153B 05 | 2 | -- |
Object Sensors Signal | B153F 02 | B153F 05 | B153F 05 | B153F 03, B153F 07 |
Open/Close Switches Signal | B2494 02 | 1, 2 | 1, 2 | -- |
Pawl Switch Signal | B153A 00 | B153A 08 | B153A 00 | B153A 08 |
Position Sensor Signal 1 | B153E 08 | B153E 08 | B153E 05 | -- |
Position Sensor Signal 2 | B153E 08 | B153A 08 | B153E 05 | B153E 08 |
Ratchet Switch Signal | B153A 00 | B153A 08 | B153A 00 | B153A 08 |
Sector Switch Signal | B153A 00 | B153A 00 | B153A 00 | B153A 08 |
Disengage Clutch Control | B396B 02 | B396B 04 | B396B 01 | -- |
Engage Clutch Control | B396B 02 | B396B 04 | B396B 01 | -- |
Liftgate Latch Cinch Control | B2495 02 | B2495 04 | B2495 01 | -- |
Liftgate Latch Release Control | B2495 02 | B2495 04 | B2495 01 | -- |
Liftgate Motor Close Control | B396A 02 | B396A 04 | B396A 01 | B153E 08 |
Liftgate Motor Open Control | B396A 02 | B396A 04 | B396A 01 | B153E 08 |
Full Open Low Reference | -- | B153B 05 | 2 | -- |
Liftgate Switches Low Reference | -- | B153A 08 | 1 | B153E 08 |
Position Sensor Low Reference | -- | B153E 08 | 2 | -- |
Liftgate Control Module Ground | -- | U0230 00 | 2 | -- |
1. Liftgate Switch Malfunction 2. Liftgate Malfunction |
The liftgate module (LGM) supplies power and ground to the liftgate clutch, which is part of the liftgate motor assembly. Upon receiving a liftgate open request, the LGM supplies voltage to the clutch via the liftgate motor engage control circuit. The liftgate motor disengage control circuit supplies a ground. With the clutch energized, the motor output is mechanically connected to the liftgate and power liftgate operation is allowed. The liftgate motor clutch engages or disengages the liftgate motor to the liftgate drive gear and is the component that determines power or manual operation.
The system voltage is 9-16 volts.
The LGM detects a short to voltage in the liftgate clutch engage control circuit or the liftgate clutch disengage control circuit.
The LGM detects a short to ground in the liftgate clutch engage control circuit or the liftgate clutch disengage control circuit.
The LGM detects an open/high resistance in the liftgate clutch engage control circuit or the liftgate clutch disengage control circuit.
• | When an open or short to ground condition exists, power liftgate operation will be inoperative. |
• | When a short to voltage condition exists, the liftgate can not be opened or closed manually. |
• | The DTC will be current for as long as the fault is present. |
• | When the fault is no longer present, the DTC will be a history DTC. |
• | A history DTC will clear after 50 ignition cycles |
Whenever the LGM loses power or is disconnected, the ignition must be cycled OFF then ON in order to reactivate the LGM.
Liftgate Description and Operation
Control Module References for scan tool information
⇒ | If greater than the specified range, replace the LGM. |
⇒ | If greater than the specified range, replace the LGM. |
⇒ | If less than the specified range, test either control circuit for a short to ground. If the circuits test normal, replace the liftgate motor assembly. |
⇒ | If greater than the specified range, test either control circuit for a short to voltage or an open/high resistance. If the circuits test normal, replace the liftgate motor assembly. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for LGM replacement, setup, and programming |