Table 1: Engine Control Module (ECM) Scan Tool Output Controls
Table 2: HVAC Control Module Scan Tool Output Controls

Engine Control Module (ECM) Scan Tool Output Controls

Scan Tool Output Control

Additional Menu Selection(s)

Description

Fan Relay 1

Fan Relays

The scan tool displays a Commanded State of None, Off or On. This allows you to communicate with the PCM and activate or deactivate the cooling fan 1 relay, manually turning the low speed fans On and Off.

Fan Relay 2

Fan Relays

The scan tool displays a Commanded State of None, Off or On. This allows you to communicate with the PCM to activate or deactivate the cooling fan 1 relay, manually turning the low speed fans On. After a 3 second delay the PCM will activate the cooling fan 2 relay and the cooling fan 3 relay. This turns the high speed fans On and Off.

HVAC Control Module Scan Tool Output Controls

Scan Tool Output Control

Additional Menu Selection(s)

Description

Water Pump Relay

Miscellaneous Tests

The scan tool displays a Commanded State of None, Off or On. This allows you to communicate with the HVAC control module, and activate or deactivate the after-boil relay, manually turning the after-boil coolant pump On and Off.