Table 1: | Instrument Panel Module (IPM) Scan Tool Data List |
Table 2: | Memory Seat Module (MSM) Scan Tool Data List |
Table 3: | Steering Column Lock Control Module (SCLCM) Scan Tool Data List |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Turn the Ignition ON, with the Engine OFF | |||
Battery Voltage Signal | Load Management | Volts | 12.6 V |
Column Lock Relay | Outputs | Enabled/Disabled | Enabled |
Telescope Forward Switch | Inputs | Active/Inactive | Inactive |
Telescope Rearward Switch | Inputs | Active/Inactive | Inactive |
Tilt Down Switch | Inputs | Active/Inactive | Inactive |
Tilt Up Switch | Inputs | Active/Inactive | Inactive |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Default Telescope Exit Position | Telescope Sensor | Volts | 3.76 V |
Default Tilt Exit Position | Tilt Sensor | Volts | 3.76 V |
Driver 1 Memorized Position | Telescope Sensor | Volts/Counts | 0.7-3.2 V (45-157 Counts) |
Driver 1 Memorized Position | Tilt Sensor | Volts/Counts | 1.6-4.2 V (88-207 Counts) |
Driver 2 Memorized Position | Telescope Sensor | Volts/Counts | 0.7-3.2 V (45-157 Counts) |
Driver 2 Memorized Position | Tilt Sensor | Volts/Counts | 1.6-4.2 V (88-207 Counts) |
Memory 1 Telescope Exit Position | Telescope Sensor | Volts | Varies |
Memory 1 Tilt Exit Position | Tilt Sensor | Volts | Varies |
Memory 2 Telescope Exit Position | Telescope Sensor | Volts | Varies |
Memory 2 Tilt Exit Position | Tilt Sensor | Volts | Varies |
Telescope Forward Command | Telescope Sensor | On/Off | Off |
Telescope Rearward Command | Telescope Sensor | On/Off | Off |
Telescope Sensor | Telescope Sensor | Volts/Counts | 0.7-3.2 V (45-157 Counts) |
Telescope Soft Stops Learned | Telescope Sensor | Yes/No | Yes |
Tilt Down Command | Tilt Sensor | On/Off | Off |
Tilt Sensor | Tilt Sensor | Volts/Counts | 1.6-4.2 V (88-207 Counts) |
Tilt Soft Stops Learned | Tilt Sensor | Yes/No | Yes |
Tilt Up Command | Tilt Sensor | On/Off | Off |
Scan Tool Parameter | Data List | Units Displayed | Typical Data Value |
---|---|---|---|
Column Lock Relay Command | BCM | On/Off | On |
Column Lock Relay Signal | BCM | On/Off | On |