Removal Procedure
- Remove the knee bolster trim. Refer to
Knee Bolster Replacement
in Instrument Panel, Gages, and Console.
- Remove the screws (1) securing the data link connector
to the instrument panel (I/P).
Installation Procedure
- Locate the connector to the I/P.
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws (1) securing the connector to the I/P.
Tighten
Tighten the screws (1) to 2 N·m (18 lb in).
- Install the knee bolster trim. Refer to
Knee Bolster Replacement
in Instrument Panel, Gages, and Console.