Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Master Electrical Component List | |||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||
2 |
Does the Park Lamp Switch data parameter display ON? | Go to Step 4 | Go to Step 3 | ||||||
3 |
Does the Park Lamp Switch data parameter display ON? | Go to Step 10 | Go to Step 6 | ||||||
4 |
Does the test lamp illuminate? | Go to Step 8 | Go to Step 5 | ||||||
5 | Test the park lamp relay control circuit for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 12 | ||||||
6 | Locate and repair an open or high resistance in the turn signal/multifunction switch ground circuit. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 7 | ||||||
7 | Locate and repair the following in the park lamp switch ON signal circuit:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 12 | ||||||
8 |
Do all of the park lamps illuminate? | Go to Step 11 | Go to Step 9 | ||||||
9 | Locate and repair on open or high resistance in the inoperative park lamp supply voltage circuit. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 13 | ||||||
10 | Inspect for poor connections at the harness connector of the turn signal/multifunction switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 14 | ||||||
11 | Inspect for poor connections at the park lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 15 | ||||||
12 | Inspect for poor connections at the harness connector of the IPM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 17 | Go to Step 16 | ||||||
13 | Locate and repair on open or high resistance in the inoperative park lamp ground circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | Go to Step 17 | -- | ||||||
14 | Replace the turn signal/multifunction switch. Refer to Turn Signal Multifunction Switch Replacement . Did you complete the replacement? | Go to Step 17 | -- | ||||||
15 | Replace the park lamp relay. Refer to Relay Replacement . Did you complete the replacement? | Go to Step 17 | -- | ||||||
16 | Replace the IPM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 17 | -- | ||||||
17 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |