GM Service Manual Online
For 1990-2009 cars only

Air Conditioning (A/C) System Performance Test LH2 w/ Standard Cooling

Table 1: A/C Performance Table

Test Description

This test measures the operating efficiency of the A/C system under the following conditions:

    • The current ambient air temperature
    • The current relative humidity
    • The high side pressure of the A/C system
    • The low side pressure of the A/C system
    • The temperature of the air being discharged into the passenger compartment

The numbers below refer to the step numbers on the diagnostic table.

  1. This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.

  2. This step measures the performance of the A/C system.

  3. This step is to allow for vehicle variations as well as high ambient temperatures.

Step

Action

Values

Yes

No

Important: 

   • The ambient air temperature must be at least 16°C (60°F) .
   • Do not induce additional air flow across the front of the vehicle during the test.
   • If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test.

1

  1. Park the vehicle inside or in the shade.
  2. Open the windows in order to ventilate the interior of the vehicle.
  3. If the A/C system was operating, allow the A/C system to equalize for about 5 minutes.
  4. Turn OFF the ignition.
  5. Install the J 43600 ACR 2000 Air Conditioning Service Center.
  6. Record the ambient air temperature displayed on the J 43600 .
  7. Record the low and high side STATIC pressure readings.

Are both the low side and high side pressures above the specified value?

More than 16°C (60°F) - 345 kPa (50 psi)

More than 24°C (75°F) - 483 kPa (70 psi)

More than 33°C (90°F) - 690 kPa (100 psi)

Go to Step 2

Go to Leak Testing

2

    Important: Record the relative humidity and the ambient air temperature at the time of the test.

  1. Close the vehicle doors and windows.
  2. Open the driver door window 12.7-15.2 cm (5-6 inches).
  3. Select the following HVAC control settings:
  4. • The A/C is ON
    • The maximum blower speed
    • The maximum blower speed selected on the auxiliary blower controls
    • Recirculation mode
    • The Face mode
    • The coldest temperature setting
    • Passenger setting is OFF
    • All A/C outlets are OPEN
  5. Install the temperature probes of the J 43600 in the left and right center A/C air outlets.
  6. Apply the parking brake.
  7. Place the transaxle/transmission in the following position: PARK.
  8. Start the engine.
  9. Operate the A/C system for 5 minutes.
  10. Inspect A/C components for the following conditions:
  11. • Abnormal frost areas
    • Unusual noises

    Important: Make sure that the compressor is engaged when taking the data.

    Press the RESET button, before using the print function of the J 43600 .

  12. Print the following information:
  13. • The outlet air temperatures
    • The low-side pressure
    • The high-side pressure
  14. Compare the low and high side pressures and the output temperatures to the A/C Performance Table.

Does all the data recorded fall within the specified ranges of the A/C Performance Table?

--

Go to Step 8

Go to Step 3

3

If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:

  1. Continue to operate the A/C system for an additional 5 minutes.
  2. RESET the J 43600 and record the pressures and temperatures again.
  3. Compare the low and high side pressures and the output temperature to the A/C Performance Table.

Does all the data recorded fall within the specified ranges?

--

Go to Step 8

Go to Step 4

4

Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A

Go to Step 5

5

Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B

Go to Step 6

6

Are the low and high side pressures both greater than the specified ranges?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C

Go to Step 7

7

Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D

Go to Step 8

8

Operate the system in order to verify the test results.

Did you find the same results?

--

System OK

Go to Symptoms - HVAC Systems - Automatic

A/C Performance Table

Ambient Temperature

Relative Humidity

Low Side Service Port Pressure

High Side Service Port Pressure

Maximum Left Center Discharge Air Temperature

Maximum Left Side Rear Discharge Air Temperature

13-18°C (55-65°F)

0-100%

170-234 kPa (25-34 psi)

1101-1411 kPa (160-205 psi)

8°C (46°F)

11°C (52°F)

19-24°C (66-75°F)

Less than 40%

187-263 kPa (27-38 psi)

1241-1503 kPa (180-218 psi)

11°C (52°F)

14°C (57°F)

Greater than 40%

194-271 kPa (28-39 psi)

1231-1551 kPa (179-225 psi)

12°C (54°F)

14°C (57°F)

25-29°C (76-85°F)

Less than 35%

218-286 kPa (32-42 psi)

1341-1591 kPa (194-231 psi)

13°C (55°F)

16°C (61°F)

35-60%

193-276 kPa (28-40 psi)

1310-1551 kPa (190-225 psi)

14°C (57°F)

16°C (61°F)

Greater than 60%

225-294 kPa (33-43 psi)

1393-1634 kPa (202-237 psi)

14°C (57°F)

17°C (63°F)

30-35°C (86-95°F)

Less than 30%

242-314 kPa (35-46 psi)

1471-1741 kPa (213-2531 psi)

16°C (61°F)

19°C (66°F)

30-50%

245-317 kPa (36-46 psi)

1501-1761 kPa (218-255 psi)

17°C (63°F)

19°C (66°F)

Greater than 50%

249-322 kPa (36-47 psi)

1531-1801 kPa (222-261 psi)

17°C (63°F)

20°C (68°F)

36-41°C (96-105°F)

Less than 20%

271-342 kPa (39-50 psi)

1631-1881 kPa (237-273 psi)

18°C (64°F)

21°C (70°F)

20-40%

273-345 kPa (40-50 psi)

1593-1827 kPa (231-265 psi)

19°C (66°F)

22°C (72°F)

Greater than 40%

276-359 kPa (40-52 psi)

1848-2041 kPa (268-296 psi)

20°C (68°F)

22°C (72°F)

42-46°C (106-115°F)

Less than 20%

301-367 kPa (44-53 psi)

1841-2048 kPa (267-297 psi)

20°C (68°F)

23°C (73°F)

Greater than 20%

302-369 kPa (44-54 psi)

1801-2031 kPa (261-295 psi)

21°C (70°F)

24°C (75°F)

47-49°C (116-120°F)

Less than 30%

296-365 kPa (43-53 psi)

1868-2075 kPa (271-301 psi)

22°C (72°F)

25°C (77°F)

LH2 With Standard Cooling


Object Number: 1474315  Size: MF

Air Conditioning (A/C) System Performance Test LY7 w/Standard Cooling

Table 1: A/C Performance Table

Test Description

This test measures the operating efficiency of the A/C system under the following conditions:

    • The current ambient air temperature
    • The current relative humidity
    • The high side pressure of the A/C system
    • The low side pressure of the A/C system
    • The temperature of the air being discharged into the passenger compartment

The numbers below refer to the step numbers on the diagnostic table.

  1. This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.

  2. This step measures the performance of the A/C system.

  3. This step is to allow for vehicle variations as well as high ambient temperatures.

Step

Action

Values

Yes

No

Important: 

   • The ambient air temperature must be at least 16°C (60°F) .
   • Do not induce additional air flow across the front of the vehicle during the test.
   • If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test.

1

  1. Park the vehicle inside or in the shade.
  2. Open the windows in order to ventilate the interior of the vehicle.
  3. If the A/C system was operating, allow the A/C system to equalize for about 5 minutes.
  4. Turn OFF the ignition.
  5. Install the J 43600 ACR 2000 Air Conditioning Service Center.
  6. Record the ambient air temperature displayed on the J 43600 .
  7. Record the low and high side STATIC pressure readings.

Are both the low side and high side pressures above the specified value?

More than 16°C (60°F) - 345 kPa (50 psi)

More than 24°C (75°F) - 483 kPa (70 psi)

More than 33°C (90°F) - 690 kPa (100 psi)

Go to Step 2

Go to Leak Testing

2

    Important: Record the relative humidity and the ambient air temperature at the time of the test.

  1. Close the vehicle doors and windows.
  2. Open the driver door window 12.7-15.2 cm (5-6 in).
  3. Select the following HVAC control settings:
  4. • The A/C is ON.
    • The maximum blower speed
    • The maximum blower speed selected on the auxiliary blower controls
    • Recirculation mode
    • The Face mode
    • The coldest temperature setting
    • Passenger setting is OFF
    • All A/C outlets are OPEN.
  5. Install the temperature probes of the J 43600 in the left and right center A/C air outlets.
  6. Apply the parking brake.
  7. Place the transaxle/transmission in the following position: PARK.
  8. Start the engine.
  9. Operate the A/C system for 5 minutes.
  10. Inspect A/C components for the following conditions:
  11. • Abnormal frost areas
    • Unusual noises

    Important: Make sure that the compressor is engaged when taking the data.

    Press the RESET button, before using the print function of the J 43600 .

  12. Print the following information:
  13. • The outlet air temperatures
    • The low-side pressure
    • The high-side pressure
  14. Compare the low and high side pressures and the output temperatures to the A/C Performance Table.

Does all the data recorded fall within the specified ranges of the A/C Performance Table?

--

Go to Step 8

Go to Step 3

3

If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:

  1. Continue to operate the A/C system for an additional 5 minutes.
  2. RESET the J 43600 and record the pressures and temperatures again.
  3. Compare the low and high side pressures and the output temperature to the A/C Performance Table.

Does all the data recorded fall within the specified ranges?

--

Go to Step 8

Go to Step 4

4

Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A

Go to Step 5

5

Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B

Go to Step 6

6

Are the low and high side pressures both greater than the specified ranges?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C

Go to Step 7

7

Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D

Go to Step 8

8

Operate the system in order to verify the test results.

Did you find the same results?

--

System OK

Go to Symptoms - HVAC Systems - Automatic

A/C Performance Table

Ambient Temperature

Relative Humidity

Low Side Service Port Pressure

High Side Service Port Pressure

Maximum Left Center Discharge Air Temperature

Maximum Left Side Rear Discharge Air Temperature

13-18°C (55-65°F)

0-100%

150-221 kPa (22-32 psi)

1191-1441 kPa (173-209 psi)

10°C (50°F)

11°C (52°F)

19-24°C (66-75°F)

Less than 40%

153-239 kPa (22-35 psi)

1303-1524 kPa (189-221 psi)

11°C (52°F)

13°C (55°F)

Greater than 40%

169-257 kPa (25-37 psi)

1338-1558 kPa (184-226 psi)

12°C (54°F)

14°C (57°F)

25-29°C (76-85°F)

Less than 35%

187-261 kPa (27-38 psi)

1391-1591 kPa (202-231 psi)

13°C (55°F)

15°C (59°F)

35-60%

196-262 kPa (28-38 psi)

1411-1634 kPa (205-237 psi)

14°C (57°F)

15°C (59°F)

Greater than 60%

203-280 kPa (29-41 psi)

1517-1696 kPa (220-246 psi)

15°C (59°F)

16°C (61°F)

30-35°C (86-95°F)

Less than 30%

213-289 kPa (31-42 psi)

1511-1721 kPa (219-250 psi)

16°C (61°F)

18°C (64°F)

30-50%

219-296 kPa (32-43 psi)

1511-1711 kPa (219-248 psi)

17°C (63°F)

18°C (64°F)

Greater than 50%

227-307 kPa (33-45 psi)

1482-1682 kPa (215-244 psi)

18°C (64°F)

19°C (66°F)

36-41°C (96-105°F)

Less than 20%

242-316 kPa (35-46 psi)

1613-1820 kPa (234-264 psi)

18°C (64°F)

20°C (68°F)

20-40%

245-322 kPa (36-47 psi)

1651-1841 kPa (239-267 psi)

19°C (66°F)

21°C (70°F)

Greater than 40%

252-328 kPa (37-48 psi)

1631-1811 kPa (237-263 psi)

20°C (68°F)

21°C (70°F)

42-46°C (106-115°F)

Less than 20%

273-342 kPa (40-50 psi)

1801-1981 kPa (261-287 psi)

21°C (70°F)

23°C (73°F)

Greater than 20%

276-346 kPa (40-50 psi)

1791-1941 kPa (260-282 psi)

21°C (70°F)

23°C (73°F)

47-49°C (116-120°F)

Less than 30%

302-359 kPa (44-52 psi)

2075-2186 kPa (301-317 psi)

22°C (72°F)

25°C (75°F)

LY7 With Standard Cooling


Object Number: 1418634  Size: MF

Air Conditioning (A/C) System Performance Test LH2 w/ Heavy Duty Cooling

Table 1: A/C Performance Table

Test Description

This test measures the operating efficiency of the A/C system under the following conditions:

    • The current ambient air temperature
    • The current relative humidity
    • The high side pressure of the A/C system
    • The low side pressure of the A/C system
    • The temperature of the air being discharged into the passenger compartment

The numbers below refer to the step numbers on the diagnostic table.

  1. This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.

  2. This step measures the performance of the A/C system.

  3. This step is to allow for vehicle variations as well as high ambient temperatures.

Step

Action

Values

Yes

No

Important: 

   • The ambient air temperature must be at least 16°C (60°F) .
   • Do not induce additional air flow across the front of the vehicle during the test.
   • If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test.

1

  1. Park the vehicle inside or in the shade.
  2. Open the windows in order to ventilate the interior of the vehicle.
  3. If the A/C system was operating, allow the A/C system to equalize for about 5 minutes.
  4. Turn OFF the ignition.
  5. Install the J 43600 ACR 2000 Air Conditioning Service Center.
  6. Record the ambient air temperature displayed on the J 43600 .
  7. Record the low and high side STATIC pressure readings.

Are both the low side and high side pressures above the specified value?

More than 16°C (60°F) - 345 kPa (50 psi)

More than 24°C (75°F) - 483 kPa (70 psi)

More than 33°C (90°F) - 690 kPa (100 psi)

Go to Step 2

Go to Leak Testing

2

    Important: Record the relative humidity and the ambient air temperature at the time of the test.

  1. Close the vehicle doors and windows.
  2. Open the driver door window 12.7-15.2 cm (5-6 inches).
  3. Select the following HVAC control settings:
  4. • The A/C is ON
    • The maximum blower speed
    • The maximum blower speed selected on the auxiliary blower controls
    • Recirculation mode
    • The Face mode
    • The coldest temperature setting
    • Passenger setting is OFF
    • All A/C outlets are OPEN
  5. Install the temperature probes of the J 43600 in the left and right center A/C air outlets.
  6. Apply the parking brake.
  7. Place the transaxle/transmission in the following position: PARK.
  8. Start the engine.
  9. Operate the A/C system for 5 minutes.
  10. Inspect A/C components for the following conditions:
  11. • Abnormal frost areas
    • Unusual noises

    Important: Make sure that the compressor is engaged when taking the data.

    Press the RESET button, before using the print function of the J 43600 .

  12. Print the following information:
  13. • The outlet air temperatures
    • The low-side pressure
    • The high-side pressure
  14. Compare the low and high side pressures and the output temperatures to the A/C Performance Table.

Does all the data recorded fall within the specified ranges of the A/C Performance Table?

--

Go to Step 8

Go to Step 3

3

If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:

  1. Continue to operate the A/C system for an additional 5 minutes.
  2. RESET the J 43600 and record the pressures and temperatures again.
  3. Compare the low and high side pressures and the output temperature to the A/C Performance Table.

Does all the data recorded fall within the specified ranges?

--

Go to Step 8

Go to Step 4

4

Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A

Go to Step 5

5

Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B

Go to Step 6

6

Are the low and high side pressures both greater than the specified ranges?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C

Go to Step 7

7

Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D

Go to Step 8

8

Operate the system in order to verify the test results.

Did you find the same results?

--

System OK

Go to Symptoms - HVAC Systems - Automatic

A/C Performance Table

Ambient Temperature

Relative Humidity

Low Side Service Port Pressure

High Side Service Port Pressure

Maximum Left Center Discharge Air Temperature

Maximum Left Side Rear Discharge Air Temperature

13-18°C (55-65°F)

0-100%

164-231 kPa (24-34 psi)

1338-1565 kPa (194-227 psi)

10°C (50°F)

11°C (52°F)

19-24°C (66-75°F)

Less than 40%

191-272 kPa (28-39 psi)

1524-1675 kPa (221-243 psi)

12°C (54°F)

13°C (55°F)

Greater than 40%

195-288 kPa (28-42 psi)

1411-1691 kPa (205-245 psi)

13°C (55°F)

15°C (59°F)

25-29°C (76-85°F)

Less than 35%

222-300 kPa (32-44 psi)

1524-1731 kPa (221-251 psi)

15°C (59°F)

16°C (61°F)

35-60%

230-310 kPa (33-45 psi)

1561-1781 kPa (226-258 psi)

15°C (59°F)

17°C (63°F)

Greater than 60%

236-328 kPa (34-49 psi)

1581-1821 kPa (229-264 psi)

16°C (61°F)

18°C (64°F)

30-35°C (86-95°F)

Less than 30%

248-332 kPa (36-48 psi)

1661-1868 kPa (241-271 psi)

17°C (63°F)

19°C (66°F)

30-50%

257-349 kPa (37-51 psi)

1681-1924 kPa (244-279 psi)

18°C (64°F)

20°C (68°F)

Greater than 50%

270-375 kPa (39-54 psi)

1701-1981 kPa (247-287 psi)

20°C (68°F)

22°C (72°F)

36-41°C (96-105°F)

Less than 20%

275-355 kPa (40-52 psi)

1811-2051 kPa (263-298 psi)

19°C (66°F)

21°C (70°F)

20-40%

283-378 kPa (41-55 psi)

1821-2081 kPa (264-302 psi)

21°C (70°F)

22°C (72°F)

Greater than 40%

301-400 kPa (44-58 psi)

1917-2137 kPa (278-310 psi)

22°C (72°F)

24°C (75°F)

42-46°C (106-115°F)

Less than 20%

304-382 kPa (44-55 psi)

2006-2193 kPa (291-318 psi)

22°C (72°F)

23°C (73°F)

Greater than 20%

315-414 kPa (46-60 psi)

2027-2261 kPa (294-328 psi)

23°C (73°F)

25°C (77°F)

47-49°C (116-120°F)

Less than 30%

331-413 kPa (51-62 psi)

2091-2272 kPa (303-329 psi)

24°C (75°F)

26°C (79°F)

LH2 With Heavy Duty Cooling


Object Number: 1471767  Size: MF

Air Conditioning (A/C) System Performance Test LY7 w/ Heavy Duty Cooling

Table 1: A/C Performance Table

Test Description

This test measures the operating efficiency of the A/C system under the following conditions:

    • The current ambient air temperature
    • The current relative humidity
    • The high side pressure of the A/C system
    • The low side pressure of the A/C system
    • The temperature of the air being discharged into the passenger compartment

The numbers below refer to the step numbers on the diagnostic table.

  1. This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.

  2. This step measures the performance of the A/C system.

  3. This step is to allow for vehicle variations as well as high ambient temperatures.

Step

Action

Values

Yes

No

Important: 

   • The ambient air temperature must be at least 16°C (60°F) .
   • Do not induce additional air flow across the front of the vehicle during the test.
   • If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test.

1

  1. Park the vehicle inside or in the shade.
  2. Open the windows in order to ventilate the interior of the vehicle.
  3. If the A/C system was operating, allow the A/C system to equalize for about 5 minutes.
  4. Turn OFF the ignition.
  5. Install the J 43600 ACR 2000 Air Conditioning Service Center.
  6. Record the ambient air temperature displayed on the J 43600 .
  7. Record the low and high side STATIC pressure readings.

Are both the low side and high side pressures above the specified value?

More than 16°C (60°F) - 345 kPa (50 psi)

More than 24°C (75°F) - 483 kPa (70 psi)

More than 33°C (90°F) - 690 kPa (100 psi)

Go to Step 2

Go to Leak Testing

2

    Important: Record the relative humidity and the ambient air temperature at the time of the test.

  1. Close the vehicle doors and windows.
  2. Open the driver door window 12.7-15.2 cm (5-6 inches).
  3. Select the following HVAC control settings:
  4. • The A/C is ON
    • The maximum blower speed
    • The maximum blower speed selected on the auxiliary blower controls
    • Recirculation mode
    • The Face mode
    • The coldest temperature setting
    • Passenger setting is OFF
    • All A/C outlets are OPEN
  5. Install the temperature probes of the J 43600 in the left and right center A/C air outlets.
  6. Apply the parking brake.
  7. Place the transaxle/transmission in the following position: PARK.
  8. Start the engine.
  9. Operate the A/C system for 5 minutes.
  10. Inspect A/C components for the following conditions:
  11. • Abnormal frost areas
    • Unusual noises

    Important: Make sure that the compressor is engaged when taking the data.

    Press the RESET button, before using the print function of the J 43600 .

  12. Print the following information:
  13. • The outlet air temperatures
    • The low-side pressure
    • The high-side pressure
  14. Compare the low and high side pressures and the output temperatures to the A/C Performance Table.

Does all the data recorded fall within the specified ranges of the A/C Performance Table?

--

Go to Step 8

Go to Step 3

3

If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:

  1. Continue to operate the A/C system for an additional 5 minutes.
  2. RESET the J 43600 and record the pressures and temperatures again.
  3. Compare the low and high side pressures and the output temperature to the A/C Performance Table.

Does all the data recorded fall within the specified ranges?

--

Go to Step 8

Go to Step 4

4

Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A

Go to Step 5

5

Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B

Go to Step 6

6

Are the low and high side pressures both greater than the specified ranges?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C

Go to Step 7

7

Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D

Go to Step 8

8

Operate the system in order to verify the test results.

Did you find the same results?

--

System OK

Go to Symptoms - HVAC Systems - Automatic

A/C Performance Table

Ambient Temperature

Relative Humidity

Low Side Service Port Pressure

High Side Service Port Pressure

Maximum Left Center Discharge Air Temperature

Maximum Left Side Rear Discharge Air Temperature

13-18°C (55-65°F)

0-100%

153-221 kPa (22-30 psi)

861-1121 kPa (125-163 psi)

11°C (52°F)

12°C (54°F)

19-24°C (66-75°F)

Less than 40%

180-262 kPa (26-38 psi)

1069-1291 kPa (155-187 psi)

14°C (57°F)

15°C (59°F)

Greater than 40%

185-274 kPa (27-40 psi)

1048-1311 kPa (152-190 psi)

14°C (57°F)

15°C (59°F)

25-29°C (76-85°F)

Less than 35%

215-292 kPa (31-42 psi)

1201-1441 kPa (174-209 psi)

16°C (61°F)

17°C (63°F)

35-60%

221-298 kPa (32-43 psi)

1248-1475 kPa (181-214 psi)

16°C (61°F)

18°C (64°F)

Greater than 60%

225-311 kPa (33-45 psi)

1262-1510 kPa (183-219 psi)

17°C (63°F)

19°C (66°F)

30-35°C (86-95°F)

Less than 30%

244-326 kPa (35-47 psi)

1386-1648 kPa (201-239 psi)

18°C (646°F)

20°C (68°F)

30-50%

250-338 kPa (36-49 psi)

1361-1662 kPa (197-241 psi)

19°C (66°F)

21°C (70°F)

Greater than 50%

258-354 kPa (37-51 psi)

1371-1682 kPa (199-244 psi)

20°C (68°F)

22°C (72°F)

36-41°C (96-105°F)

Less than 20%

275-356 kPa (40-52 psi)

1541-1758 kPa (224-264 psi)

20°C (68°F)

23°C (73°F)

20-40%

281-370 kPa (41-54 psi)

1551-1821 kPa (225-264 psi)

22°C (72°F)

24°C (75°F)

Greater than 40%

292-384 kPa (42-56 psi)

1551-1831 kPa (225-266 psi)

23°C (73°F)

25°C (77°F)

42-46°C (106-115°F)

Less than 20%

309-385 kPa (45-56 psi)

1731-1971 kPa (251-286 psi)

23°C (73°F)

25°C (77°F)

Greater than 20%

316-401 kPa (46-58 psi)

1741-1981 kPa (253-287 psi)

24°C (75°F)

27°C (81°F)

47-49°C (116-120°F)

Less than 30%

345-411 kPa (50-61 psi)

1965-2193 kPa (285-318 psi)

25°C (77°F)

28°C (82°F)

LY7 With Heavy Duty Cooling


Object Number: 1471776  Size: MF

Air Conditioning (A/C) System Performance Test LC3

Table 1: A/C Performance Table

Test Description

This test measures the operating efficiency of the A/C system under the following conditions:

    • The current ambient air temperature
    • The current relative humidity
    • The high side pressure of the A/C system
    • The low side pressure of the A/C system
    • The temperature of the air being discharged into the passenger compartment

The numbers below refer to the step numbers on the diagnostic table.

  1. This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.

  2. This step measures the performance of the A/C system.

  3. This step is to allow for vehicle variations as well as high ambient temperatures.

Step

Action

Values

Yes

No

Important: 

   • The ambient air temperature must be at least 16°C (60°F) .
   • Do not induce additional air flow across the front of the vehicle during the test.
   • If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test.

1

  1. Park the vehicle inside or in the shade.
  2. Open the windows in order to ventilate the interior of the vehicle.
  3. If the A/C system was operating, allow the A/C system to equalize for about 5 minutes.
  4. Turn OFF the ignition.
  5. Install the J 43600 ACR 2000 Air Conditioning Service Center.
  6. Record the ambient air temperature displayed on the J 43600 .
  7. Record the low and high side STATIC pressure readings.

Are both the low side and high side pressures above the specified value?

More than 16°C (60°F) - 345 kPa (50 psi)

More than 24°C (75°F) - 483 kPa (70 psi)

More than 33°C (90°F) - 690 kPa (100 psi)

Go to Step 2

Go to Leak Testing

2

    Important: Record the relative humidity and the ambient air temperature at the time of the test.

  1. Close the vehicle doors and windows.
  2. Open the driver door window 12.7-15.2 cm (5-6 inches).
  3. Select the following HVAC control settings:
  4. • The A/C is ON
    • The maximum blower speed
    • The maximum blower speed selected on the auxiliary blower controls
    • Recirculation mode
    • The Face mode
    • The coldest temperature setting
    • Passenger setting is OFF
    • All A/C outlets are OPEN
  5. Install the temperature probes of the J 43600 in the left and right center A/C air outlets.
  6. Apply the parking brake.
  7. Place the transaxle/transmission in the following position: PARK.
  8. Start the engine.
  9. Operate the A/C system for 5 minutes.
  10. Inspect A/C components for the following conditions:
  11. • Abnormal frost areas
    • Unusual noises

    Important: Make sure that the compressor is engaged when taking the data.

    Press the RESET button, before using the print function of the J 43600 .

  12. Print the following information:
  13. • The outlet air temperatures
    • The low-side pressure
    • The high-side pressure
  14. Compare the low and high side pressures and the output temperatures to the A/C Performance Table.

Does all the data recorded fall within the specified ranges of the A/C Performance Table?

--

Go to Step 8

Go to Step 3

3

If the pressures and temperatures recorded do not fall within the specified ranges of the A/C Performance Table:

  1. Continue to operate the A/C system for an additional 5 minutes.
  2. RESET the J 43600 and record the pressures and temperatures again.
  3. Compare the low and high side pressures and the output temperature to the A/C Performance Table.

Does all the data recorded fall within the specified ranges?

--

Go to Step 8

Go to Step 4

4

Do the high and low side pressures fall within the specified ranges, but the outlet temperatures do not?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A

Go to Step 5

5

Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B

Go to Step 6

6

Are the low and high side pressures both greater than the specified ranges?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C

Go to Step 7

7

Is the high side pressure greater than or within the specified range, but the low side pressure is less than the specified range?

--

Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D

Go to Step 8

8

Operate the system in order to verify the test results.

Did you find the same results?

--

System OK

Go to Symptoms - HVAC Systems - Automatic

A/C Performance Table

Ambient Temperature

Relative Humidity

Low Side Service Port Pressure

High Side Service Port Pressure

Maximum Left Center Discharge Air Temperature

Maximum Left Side Rear Discharge Air Temperature

13-18°C (55-65°F)

0-100%

172-241 kPa (25-35 psi)

1570-1791 kPa (228-260 psi)

8°C (46°F)

10°C (50°F)

19-24°C (66-75°F)

Less than 40%

199-289 kPa (29-42 psi)

1818-2101 kPa (264-305 psi)

13°C (54°F)

15°C (59°F)

Greater than 40%

206-296 kPa (30-43 psi)

1770-2067 kPa (257-300 psi)

13°C (54°F)

15°C (59°F)

25-29°C (76-85°F)

Less than 35%

241-323 kPa (35-47 psi)

2053-2308 kPa (298-335 psi)

14°C (57°F)

18°C (64°F)

35-60%

248-323 kPa (36-47 psi)

2032-2308 kPa (295-335 psi)

15°C (59°F)

18°C (64°F)

Greater than 60%

248-337 kPa (36-49 psi)

2011-2301 kPa (292-334 psi)

17°C (61°F)

19°C (663°F)

30-35°C (86-95°F)

Less than 30%

275-358 kPa (40-52 psi)

2239-2549 kPa (325-370 psi)

18°C (64°F)

22°C (70°F)

30-50%

275-372 kPa (40-54 psi)

2232-2563 kPa (324-372 psi)

18°C (64°F)

23°C (73°F)

Greater than 50%

289-385 kPa (42-56 psi)

2232-2569 kPa (324-373 psi)

20°C (68°F)

23°C (73°F)

36-41°C (96-105°F)

Less than 20%

310-392 kPa (45-57 psi)

2466-2790 kPa (358-405 psi)

20°C (68°F)

23°C (73°F)

20-40%

316-406 kPa (46-59 psi)

2466-2811 kPa (358-408 psi)

22°C (70°F)

25°C (77°F)

Greater than 40%

323-420 kPa (47-61 psi)

2480-2831 kPa (360-411 psi)

23°C (72°F)

27°C (79°F)

42-46°C (106-115°F)

Less than 20%

344-427 kPa (50-62 psi)

2700-2983 kPa (392-433 psi)

23°C (72°F)

27°C (79°F)

Greater than 20%

351-440 kPa (51-64 psi)

2707-3010 kPa (393-437 psi)

24°C (75°F)

28°C (82°F)

47-49°C (116-120°F)

Less than 30%

385-468 kPa (56-68 psi)

2900-3196 kPa (421-464 psi)

27°C (79°F)

29°C (84°F)

LC3


Object Number: 1629106  Size: MF