GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the instrument panel (I/P) carrier. Refer to Instrument Panel Carrier Replacement .

  2. Object Number: 756324  Size: SH
  3. Disconnect the mode actuator electrical connector.

  4. Object Number: 756240  Size: SH
  5. Remove the mode actuator screws (3).

  6. Object Number: 756327  Size: SH
  7. Remove the mode actuator.

Installation Procedure


    Object Number: 756327  Size: SH
  1. Install the mode actuator.

  2. Object Number: 756240  Size: SH

    Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the mode actuator screws (2).
  4. Tighten
    Tighten the screws to 1 N·m (9 lb in).


    Object Number: 756324  Size: SH
  5. Connect the electrical connector to the actuator.
  6. Install the I/P carrier. Refer to Instrument Panel Carrier Replacement .