GM Service Manual Online
For 1990-2009 cars only

Object Number: 1874823  Size: LF

Callout

Component Name

1

NEW Fluid Pump Seal

2

Torque Converter (with Fluid Pump) Housing Assembly

Notice: Ensure the turbine shaft (O-ring) seal is not installed prior to installing the torque converter housing assembly. The seal may become cut or damaged during installation of the torque converter housing assembly.

3

Bolt

Tip

    • 6L50 Bolt M8 x 1.25 x 50 (Qty: 8)
    • 6L80 Bolt M10 x 1.5 x 50 (Qty: 9)

Notice: Refer to Fastener Notice in the Preface section.

Tighten

    • Tighten 6L50 bolts to 31 N·m (23 lb ft) in the sequence shown.
    • Tighten 6L80 bolts to 72 N·m (53 lb ft) in the sequence shown.

4

NEW Turbine Shaft (O-Ring) Seal