• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Coil Ignition Circuit | P0691, P0693 | P0480, P0481 | -- | -- |
Relay Switch Ignition Circuit | * | * | -- | -- |
Low Fan Speed Relay Control Circuit | P0691 | P0480 | P0692 | -- |
Hi Fan Speed Relay and Fan S/P Relay Control Circuit | P0693 | P0481 | P0694 | -- |
Relay Controlled Output Circuit | * | * | ** | -- |
*Fans inoperative without a DTC. **Fans always ON without a DTC. |
The engine control module (ECM) commands the fans ON in either high speed or low speed, depending on cooling requirements. In low speed, both fans are turned ON at a reduced speed. High speed has both fans turned ON at full speed.
In low speed operation, the ECM applies ground to the coil side of the low speed fan relay. This energizes the coil and applies voltage directly to the left cooling fan through the switch side of the relay. The left fan is connected in series to the right cooling fan through the de-energized series/parallel (S/P) fan relay. The series circuit operates both fans at low speed.
In high speed operation, the ECM applies a ground to the coil side of the low speed fan relay, the S/P fan relay, and the high speed fan relay. When energized, the high speed fan relay applies voltage directly to the right cooling fan through the switch side of the relay. Simultaneously, the low speed fan relay and the S/P fan relay provide ignition voltage and a direct path to ground for the left cooling fan. With both fans connected in a parallel circuit, each fan receives full voltage and operates at high speed.
• | The ignition voltage is between 8-18 volts. |
• | The engine speed is more than 40 RPM. |
• | The ECM driver transitions from ON to OFF or from OFF to ON. |
The ECM detects an open on the low speed cooling fan relay control circuit for more than 1 second.
The ECM detects an open circuit on the high speed cooling fan relay control circuit for more than 1 second.
The ECM detects a short to ground on the low speed cooling fan relay control circuit for more than 1 second.
The ECM detects a short to voltage on the low speed cooling fan relay control circuit for more than 1 second.
The ECM detects a short to ground on the high speed cooling fan relay control circuit for more than 1 second.
The ECM detects a short to voltage on the high speed cooling fan relay control circuit for more than 1 second.
DTCs P0480, P0481, P0691, P0692, P0693, and P0694 are Type B DTCs.
DTCs P0480, P0481, P0691, P0692, P0693, and P0694 are Type B DTCs.
Cooling System Description and Operation
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Important: The following test must be performed on all three fan relay circuits.
• | Low and high speed fan relays terminal 85 |
• | S/P fan relay terminal 86 |
⇒ | If the test lamp does not illuminate, test the relay coil ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the relay coil ignition circuit fuse is open, test all components connected to the ignition circuit and replace as necessary. |
Important: The following test must be performed on all three fan relay circuits.
• | Low and high speed fan relays terminal 86 |
• | S/P fan relay terminal 85 |
⇒ | If less than the specified range, test the relay coil control circuit for an open/high resistance or for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the relay coil control circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
Important: The following test must be performed on all three fan relay circuits.
⇒ | If the test lamp is always OFF, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified range, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |