GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Cadillac
🢒
2009
🢒
STS
🢒
Engine
🢒
Engine Mechanical - 2.8L, 3.0L, 3.2L, or 3.6L
🢒 Generator Bracket Replacement
Generator Bracket Replacement LC3
Removal Procedure
Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Remove the generator. Refer to
Generator Replacement
.
Remove the generator drive belt tensioner. Refer to
Drive Belt Tensioner Replacement - Generator
.
Remove the right side engine mount bracket. Refer to
Engine Mount Bracket Replacement - Right Side
.
Remove the generator bracket bolts (1, 2 and 3).
Remove the generator bracket from the engine.
Installation Procedure
Install the generator bracket to the engine.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the generator bracket bolts and tighten to
50 N·m (37 lb ft)
.
Install the right side engine mount bracket. Refer to
Engine Mount Bracket Replacement - Right Side
.
Install the generator drive belt tensioner. Refer to
Drive Belt Tensioner Replacement - Generator
.
Install the generator. Refer to
Generator Replacement
.
Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Generator Bracket Replacement LH2
Removal Procedure
Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Remove the generator. Refer to
Generator Replacement
.
Remove the generator drive belt tensioner. Refer to
Drive Belt Tensioner Replacement - Generator
.
Remove the right side engine mount bracket. Refer to
Engine Mount Bracket Replacement - Right Side
.
Remove the generator bracket bolts (1, 2 and 3).
Remove the generator bracket from the engine.
Installation Procedure
Install the generator bracket to the engine.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the generator bracket bolts and tighten to
50 N·m (37 lb ft)
.
Install the right side engine mount bracket. Refer to
Engine Mount Bracket Replacement - Right Side
.
Install the generator drive belt tensioner. Refer to
Drive Belt Tensioner Replacement - Generator
.
Install the generator. Refer to
Generator Replacement
.
Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Generator Bracket Replacement LY7 and LLT
Removal Procedure
Turn the ignition OFF.
Remove the generator. Refer to
Generator Replacement
.
Remove the coolant inlet pipe lower bolt from the generator bracket.
Remove the belt tensioner. Refer to
Water Pump and Generator Belt Tensioner Replacement
.
Remove the generator bracket bolts.
Remove the generator bracket.
Installation Procedure
Install the generator bracket.
Install the generator bracket bolts.
Caution:
Refer to
Fastener Caution
in the Preface section.
Tighten the generator bracket bolts (1, 2) to
50 N·m (37 lb ft)
.
Tighten the generator bracket bolt (3) to
23 N·m (17 lb ft)
.
Install the belt tensioner. Refer to
Water Pump and Generator Belt Tensioner Replacement
.
Install the coolant inlet pipe lower bolt from the generator bracket.
Install the generator. Refer to
Generator Replacement
.