GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the instrument panel (I/P) carrier. Refer to Instrument Panel Carrier Replacement.

  2. Object Number: 756324  Size: SH
  3. Disconnect the mode actuator electrical connector.

  4. Object Number: 756240  Size: SH
  5. Remove the mode actuator screws (3).

  6. Object Number: 756327  Size: SH
  7. Remove the mode actuator.

Installation Procedure


    Object Number: 756327  Size: SH
  1. Install the mode actuator.
  2. Caution: Refer to Fastener Caution in the Preface section.


    Object Number: 756240  Size: SH
  3. Install the mode actuator screws (2) and tighten to 1 N·m (9 lb in ).

  4. Object Number: 756324  Size: SH
  5. Connect the electrical connector to the actuator.
  6. Install the I/P carrier. Refer to Instrument Panel Carrier Replacement.