Install the J 39686
end play check tool into the case barrel. Install the J 25025-7A
long dial indicator post.
Locate the J tab on the input shaft. The arrow on the tab should have
a 90 degree orientation.
Important: The washer must rest flat on the case cover seal.
Rotate the threaded shaft clockwise until the shaft is tight. Leave
enough space for the collar.
Insert the collar. Install the J 8001
dial indicator.
Push down on the handle and check the end play. The end play specification
is 0.10-0.85 mm (0.004-0.033 in). If the measurement
is out of the specification range, determine the appropriate selective thrust