Dash Integration Module (DIM)

After replacement of the Dash Integration Module, perform the following procedure.

  1. Using the scan tool perform the New VIN Procedure.
  2. Perform the Setup SDM Serial Number in DIM Procedure.
  3. Using the scan tool, set the Point of Sale in the DIM module to the correct country.
  4. Using the scan tool, configure RPO option configuration.
  5. Perform the vehicle Memory and Personalization Programming (Feature Programming) to reset the owner's desired personalization settings.

Procedure to Set Up A New DIM Module

  1. Connect the scan tool to the Data Link Connector (DLC).
  2. Turn ON the ignition, with the engine OFF.
  3. Under the DIM Main Menu, select Special Functions. Under the Special Functions menu, one of the choices is New VIN.
  4. The user selects one of the following:
  5. • New VIN, (to continue with the procedure).
    • Exit, to go back to Special Functions menu.
  6. After the user chooses New VIN, follow the scan tool on screen instructions to edit VIN:
  7. • Press Save to save VIN information.
    • Press Done to go back to Special Functions menu.
  8. Under the Special Functions menu, one of the choices is Setup SDM Serial Number in DIM.
  9. The user selects one of the following:
  10. • Setup SDM Serial Number in DIM, (to continue with the procedure).
    • Exit, to go back to Special Functions menu.
  11. After the user chooses Setup SDM Serial Number in DIM, the scan tool displays a screen as follows:
  12. • Do you want to set up a Dash Integration Module?
    • Press Yes to set up module.
    • Press No to Exit.
  13. Choose Yes or No
  14. • If the user selects No, the scan tool display returns to the DIM Special Function Menu.
    • If the user selects Yes, the scan tool displays Initializing New Module.
  15. Once complete, the scan tool displays Module Initialized.
  16. To complete the procedure, select the following:
  17. EXIT: Go to Special Functions Menu
  18. Under the Special Functions menu, one of the choices is Set Options.
  19. The user selects one of the following:
  20. • Set Options, (to continue with the procedure).
    • Exit, to go back to Special Functions menu.
  21. Under the Set Options menu, The user selects one of the following:
  22. • Point of Sale, (to continue with the procedure) follow the scan tool on screen instructions to Select the Point of Sale.
    • Miscellaneous Options #1, (to continue with the procedure) follow the scan tool on screen instructions to Select the RPO option configuration.
    • Miscellaneous Options #2, (to continue with the procedure) follow the scan tool on screen instructions to Select the RPO option configuration.
    • Miscellaneous Options #3, (to continue with the procedure) follow the scan tool on screen instructions to Select the RPO option configuration.
    • Exit, to go back to Special Functions menu.

Instrument Panel Module (IPM) Recalibration Procedure

Ensure the scan tool has been updated with the proper CD Rom version.

The following steps should be followed to perform the recalibration update.

  1. Connect the scan tool.
  2. The ignition should be ON, but the engine should not be operating.
  3. Select Instrument Panel Module.
  4. Select Special Functions.
  5. Select Miscellaneous Test.
  6. Select IPM Recalibration.
  7. Select RHD or LHD
  8. Select After Blow Feature
  9. Select Temperature Off Set

The scan tool will recalibrate the IPM with the latest version. To verify the proper version has been installed follow these steps:

  1. Select Data Display.
  2. Select Module Information.
  3. View the calibration ID number.

Rear Integration Module (RIM)

After replacement of the Rear Integration Module, perform the vehicle Memory and Personalization Programming (Feature Programming) to reset the owner's desired personalization settings.

Memory and Personalization Programming (Feature Programming)

If both the "ON and OFF are lit, the settings for that feature will not be able to be changed using the DIC. Both being lit indicates that a module did not respond to the cluster with personalization information when the feature programming was entered. Either the module in question, the Class 2 bus, or the cluster has a problem. If both the ON and OFF are blank (not lit), then the cluster has received invalid data from the module(s) in question and the settings for that feature will not be able to be changed using the DIC. This will typically occur when two different modules are involved in the setting (ie, Memory Seat Module and Tilt/Telescoping Module for Recall and Exit selections) and the two modules do not agree as to whether the feature is ON or OFF. This could also occur if a module sends an invalid state to the cluster. The scan tool will have to be used to toggle the feature setting for the module(s) in question so that they agree or contain valid states. Once they agree then the DIC can again be used to change the settings if needed.

  1. Turn the ignition to ON.
  2. Ensure the vehicle is in the PARK (P) position.
  3. If equipped with memory, press the appropriate memory button "1" or "2", located on the drivers door panel, prior to programming.
  4. Press the INFO button one or more times until the FEATURE PROGRAMMING prompt appears on the drivers information center (DIC) display.
  5. Press the ON/OFF button to enter FEATURE PROGRAMMING.
  6. Press the down arrow on the INFO button in order to select the personalization feature to be programmed.
  7. Press the ON/OFF button in order to turn the personalization feature on or off.
  8. To exit, press the INFO RESET button.
  9. Turn the ignition OFF.

Important: After programming, perform the following to avoid future misdiagnosis:

  1. Turn the ignition OFF for 10 seconds.
  2. Connect the scan tool to the data link connector.
  3. Turn the ignition ON with the engine OFF.
  4. Use the scan tool in order to retrieve history DTCs from all modules.
  5. Clear all history DTCs.