The RKE module runs this internal self-test at power up. This test will only be run if B1982--Battery voltage high or B1983--Battery voltage low are not current. This DTC will set as a current DTC only but will show up as test not passed since last cleared on the scan tool.
The RKE module will set this DTC if it fails the internal Read Only Memory (ROM) to Random Access Memory (RAM) write test.
Stores a DTC B1000 in the RKE current memory.
No driver warning message will be displayed for this DTC.
The RKE module will clear this DTC after a passed test message is received after the power up self-test.
This DTC will stay in memory until it receives a passed test message after the power up self-test. The DTC will show a test not passed since last cleared on the scan tool. If this DTC will not clear, replace the RKE module.
The numbers below refer to steps on the diagnostic table:
Perform the Remote Keyless Entry Diagnostic System Check before diagnosing DTC B1000.
This step is to attempt to clear the DTC.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Was the Remote Keyless Entry Diagnostic System Check preformed? | -- | |||
Is DTC B1000 still present? | -- | |||
3 | Replace the RKE module. Refer to Remote Control Door Lock Receiver Replacement . Is the repair complete? | -- | -- |