Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Charging System Check ? | -- | Go to Charging System Check | |
2 | Check the battery hydrometer. Is the green dot visible in the hydrometer? | -- | ||
3 | Diagnose the battery hydrometer. Refer to Battery Hydrometer Displays Dark or Yellow Dot . Is the charging system diagnosis complete? | -- | ||
4 | Perform the battery load test. Refer to Battery Not Operating Properly . Did the battery pass the load test? | -- | ||
5 | Replace the battery. Refer to Battery Replacement . Is the repair complete? | -- | -- | |
6 | Check the generator. Refer to Generator Not Operating Properly . Does the generator operate properly? | -- | ||
7 |
Is the voltage in the specified range? | 13-16V | ||
8 |
Is the measured voltage in the specified range? | 10-15V | ||
9 |
Is the repair complete? | -- | -- | |
10 |
Is the measured resistance in the specified range? | -- | ||
11 | Repair high resistance or open in CKT 725 (LT BLU). Is the repair complete? | -- | -- | |
12 |
Is the repair complete? | -- | -- | |
13 |
Is the charge indicator still on? | -- | ||
14 | Service the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | -- | |
15 |
Is the repair complete? | -- | -- | |
16 | Replace the generator. Refer to Generator Replacement . Is the repair complete? | -- | -- | |
17 | Repeat the Charging System Check. Refer to Charging System Check . Is the system check complete? | -- | System OK | -- |