Temperature Sensor Replacement - Low Side for Cadillac Seville 1999
Removal Procedure
Tools Required
J 39500-B A/C Refrigerant
Recovery, Recycling, and Recharging (ACR4) System
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Disconnect the electrical connector from
the sensor.
- Unscrew the sensor from the refrigerant line.
Installation Procedure
Tools Required
J 39400 Electronic Halogen
Leak Detector
- Install the sensor to the refrigerant
line.
- Connect the electrical connector to the sensor.
- Recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the system. Refer to Leak Testing
.