The RKE module runs this internal self-test at power up. This test will only be run if B1982--Battery voltage high or B1983--Battery voltage low are not current. This DTC will set as a current DTC only but will show up as test not passed since last cleared on the scan tool.
The RKE module will set this DTC if it fails the internal Read Only Memory (ROM) to Random Access Memory (RAM) write test.
The RKE module stores a DTC B1000 as current.
No driver warning message is displayed for this DTC.
The RKE module clears this DTC after the power up self-test is passed.
This DTC will stay in memory until the power up self-test is passed. The DTC will show a test not passed since last cleared on the scan tool.
The numbers below refer to steps on the diagnostic table:
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Remote Keyless Entry Diagnostic System Check preformed? | -- | ||
Is DTC B1000 still present? | -- | |||
3 | Replace the RKE module. Refer to Remote Control Door Lock Receiver Replacement . Is the repair complete? | -- | -- |