• | J 39580 Engine Support Table |
• | J 28467-A Engine Support Fixture |
19.1. | Remove the bolts (2) from the engine frame (1). |
19.2. | Remove the lower insulator retainer (3) from the lower insulator (4). |
19.3. | Remove the lower insulator (4) from the engine frame (1). |
19.4. | Remove the retainer (7) and the upper spacer (6) from the upper insulator (5). |
Remove the upper insulator (5) from the engine frame (1).
2.1. | Install the upper insulator (5) into the engine frame (1). |
2.2. | Install the retainer (7) and the upper spacer (6) onto the upper insulator (5). |
2.3. | Install the lower insulator (4) into the engine frame (1). |
2.4. | Install the lower insulator retainer (3) onto the lower insulator (4). |
2.5. | Install the bolts (2) into the engine frame (1). |
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the retainers to 191 N·m (141 lb ft).
Tighten
Tighten the retainers to 50 N·m (37 lb ft).
Tighten
Tighten the fastener to 41 N·m (30 lb ft).
Tighten
Tighten the retainer bolt to 120 N·m (89 lb ft).