Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Do the repeater lamps operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Are the turn signal lamps inoperative? | Go to Step 4 | |
4 | Are both repeater lamps inoperative? | Go to Step 8 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 9 |
6 | Connect a test lamp between the supply voltage circuit of the inoperative repeater lamp and the ground circuit of the inoperative repeater lamp. Does the test lamp illuminate? | Go to Step 7 | Go to Step 8 |
7 | Inspect for poor connections at the inoperative repeater lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
8 | Repair an open or high resistance in the ground circuit of the repeater lamps. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 11 | -- |
9 | Repair an open or high resistance in the supply voltage circuit of the inoperative repeater lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 11 | -- |
10 | Replace the inoperative repeater lamp. Refer to Repeater Lamp Replacement Did you complete the replacement? | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |