Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Fog Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Do the fog lamps operate properly? | Go to Step 3 | Go to Fog Lamps Inoperative |
3 |
Does the fog lamp indicator illuminate during the Display(s) Test? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 4 |
4 | Inspect for poor connections at the harness connector of the Instrument Cluster (IPC). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 6 | Go to Step 5 |
5 | Replace the Instrument Cluster (IPC). Refer to Instrument Cluster Replacement in Instrument Panel, Gages and Console. Did you complete the repair? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |