Removal Procedure
- Disconnect the heater hoses from the heater core. Refer to
Heater Hoses Replacement
.
- Remove the instrument panel assembly. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages
and Console.
- Remove the heat shield .
- Remove the heater core cover fasteners (1).
- Remove the heater core retaining fasteners (1).
- Remove the heater core retaining straps.
- Remove the heater core.
- Remove the heater core case seals.
Installation Procedure
- Install the heater core.
- Install the heater core retaining straps.
- Install new heater core case seals.
- Install the heater core retaining fasteners (1).
- Install the heater core cover fasteners (1).
- Install the heat shield.
- Install the instrument panel assembly. Refer to
Instrument Panel Carrier Replacement
in Instrument Panel, Gages
and Console.
- Connect the heater hoses to the heater core. Refer to
Heater Hoses Replacement
.